Misc. Fault Delay Time
0 = 15 secs
4 = 90 secs
1 = 30 secs
5 = 2 min
2 = 45 secs
6 = 2-1/2 min #+10 = 6 min #+14 = 12 min
3 = 60 secs
7 = 3 min
Used with zones assigned to a configurable zone type
with fault delay on (configurable zone type digit "6"),
and sets a zone response time of 15 seconds to 15 min.
It can be assigned to zones with sensors that provide a
trouble indication when an oil tank is low, or similar
applications for critical condition monitoring where a
non-alarm response is desired.
UL: May only be used on non-burglar alarm and non-
fire alarm zones when used on a fire and/or UL burglar
alarm installation.
*88
Program Mode Lockout Options
0 = standard *98 installer code lockout
1 = lockout [ ∗ ] + [#] reentry after *98 exit (reentry via
installer code only)
2 = lockout all local programming after *98 exit (reentry via
downloader only)
The following table summarizes the Program mode
lockout options:
Exit
*88
Reentry By:
Command Entry Installer
*99
n/a
yes
*98
0
no
*98
1
yes
*98
2
no
† pressing [∗] + [#] within 50 seconds of power up
*89
Event Log Full Report Code
0 = no report; 1-F = see description above *59
If an Event Logging selection is made in field ∗90, a
message can be sent to the central station receiver
when the log is 80% full. If the log becomes full, new
messages overwrite the oldest messages in the log.
*90
Event Log Enables
0 = no event logging; 1 = log Alarm and Restore; 2 = log
Trouble and Restore
4 = log Bypass and Restore; 8 = log Open/Close
x = log combination of events (add value of entries)
This system can record up to 100 system events in a
history log. At any time, the downloader operator can
then upload the log and view or print out all or selected
categories of the log. The downloader operator can also
clear the log. Event log can also be viewed at an alpha
keypad. The display/printout at the central station will
show the date, time, event, and description of the
occurrences.
Data Entry Example: To select Alarm/Alarm Restore"
and "Open/Close", enter 9 (1+ 8); to select all events,
enter #15.
4-6
8 = 4 min
#+12 = 8 min
9 = 5 min
#+13 = 10 min
#+11 = 7 min #+15 = 15 min
Power-up† Downloader
yes
yes
yes
yes
no
yes
no
yes
*91
Option Selection / Remote Interactive
Services (RIS) Enable
Entry 1: Options
0 = none
1 = Bell Supervision Processing†
4 = using Audio Alarm Verification (AAV) unit
8 = Enable Exit delay restart/reset ††
Entry 2: Remote Interactive Services (RIS) enable
0 = RIS disabled
1 = not applicable
2 = RIS enabled
V21iPSIA:
Entry 1 Options: Same as above.
Entry 2 Call Waiting Disable / RIS Enable:
0 = call waiting not used
1 = use call waiting disable digits (∗70) entered in field
∗40; (when selected, the system dials the entry in
∗40 only on alternate dial attempts; this allows
proper dialing in case call waiting service is later
canceled by the user).
2 = RIS (Remote Interactive Services) enabled
3 = Call Waiting disable and RIS enabled
Select by adding the values of each option.
AAV and Exit delay restart, enter # + 12 (4 + 8).
††
"Exit Delay Restart/reset" option allows use of the [∗] key to restart
the exit delay at any time when the system is armed STAY or
INSTANT. This feature also enables automatic exit delay reset, which
resets exit delay if the entry/exit door is re-opened and closed before exit
delay time expires after arming AWAY. Automatic Exit Delay Reset
occurs only once during an armed AWAY period.
IMPORTANT: AAV should not be used when Paging or Alarm
Reports are sent to a secondary number unless the monitoring
zone option is used (which pauses calls). Otherwise, the call to
the secondary number by the communicator after the alarm
report will prevent the AAV from taking control of the telephone
line, and the AAV "Listen in" session cannot take place.
Remote Interactive Services (RIS) Enable: This
option enables enhanced Remote Interactive Services
(RIS), if supported by the communication service in use.
If enabled, device address 25 is automatically assigned.
U L
UL installations using the AAV feature must use the
Honeywell AVS system.
Exit Delay Restart/Reset must be disabled.
SIA Guidelines: Exit delay should be enabled.
*92
Phone Line Monitor Enable
Entry 1–Timeout:
0 = disabled; 1-15 = 1 minute to 15 minutes respectively
(2 = 2 min, 3 = 3 min, etc.; # + 10 =10 min, # + 11 = 11 min,
# + 12 = 12 min, # + 13 = 13 min, # + 14 = 14 min, # + 15 = 15 min)
Entry 2–Display/Sound:
0 = keypad display only when phone line is faulted.
1 = keypad display plus keypad trouble sound when line is
faulted.
Each partition turns off its own trouble sound. No
automatic timeout.
2 = Same as "1" plus programmed output device STARTS.
If either partition is armed, external sounder activates. External
sounder will be turned off by normal bell timeout, or by security
code plus OFF from either partition (it does not have to be the
one that was armed).
E.g., for both

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ademco vista series vista-21ipsiaAdemco vista-21ipsiaAdemco vista-21ip

Table of Contents