Programming auto arming and disarming schedules
Hide thumbs Also See for VISTA-20P:

Advertisement

Quick Links

Step-by-Step
Programming Auto Arming and Disarming Schedules
The system provides schedules, which can be used to automatically control 11 types of system events at predefined
times. Some events are reserved for the installer only.
• VISTA-20P: Provides up to 32 schedules: 16 schedules for use by the end-user, 16 for use by the installer.
• VISTA-15P: Provides up to 8 schedules: 4 schedules for use by the end user, 4 for use by the installer.
• VISTA-10P: Provides up to 2 schedules: 1 schedule for use by the end-user, 1 for use by the installer.
NOTES:
• The master code can only access schedules 01-16 (VISTA-15P = 01-04) and events 00-07.
• System clock must be set before schedules can take effect. (See Page 2)
• Programmed schedules do not take effect until the next scheduled "start" time.
• The panel will NOT Auto Arm to a different state if already Armed
• There will be a Warning beep every 30 seconds for 10 minutes before the Auto Arming take effect. This
feature can not be disabled.
Start Scheduling mode by entering installer code + [#] + [6] [4] while in normal operating mode.
ENTER SCHEDULE NO.
00=QUIT
ENTER EVENT
01 PARTITION
START
S M T W T F S
06:00P
1 1 1 1 1 1 1
REPEAT OPTION
0-4
ENTER SCHEDULE NO.
00=QUIT
Schedule Number
01
VISTA-20P
01-16 = End-User Schedules
17-32 = Installer-Only Schedules
Press [*] to continue
Enter Desired Schedule Number.
Enter Event
00 = Clear
01 = Relay On/Off
02 = User Access
03 = Latch key Report to Pager
04 = Forced Stay Arming
Press [*] to continue
Enter the desired event for event you want to occur at a specified time.
† Forced bypass is automatically enabled regardless of the setting in field *23.
Enter the desired partition that the auto arming window will occur on.
1
Entries:
1 = Partition 1 Only
2 = Partition 2 Only
0 = Partition 1 and 2
To enable the panel to Arm Away at 6:00PM Enter the start time as 6:00PM
01-12 = hour; 00-59 = minute; 0 = AM; 1 = PM; Days = place "1" under the days for
this event to take place. Press [*] to continue.
Enter the event's start time and days off the week to occur.
To Select days, position the cursor under the desired days using the [*] key to move
forward, and then press "1" to select the day.
Repeat Option
1
Entries:
0 = Do Not Repeat
1 = Repeat Weekly
2 = Repeat Biweekly (Every Other Week)
3 = Repeat Every Third Week
4 = Repeat Every Fourth Week
In our example we want the panel to arm at 6PM and we want it to happen every day of
the week. We enabled our time and every day in the start window. Now we want this
schedule to take place every day of the week every week. So our entry would be a 1 in
this location.
Quitting
00
Enter 00 then * to quit.
VISTA-15P
01-04 = End User Schedules
05-08 = Installer-Only Schedules
05 = Forced Away Arming
06 = Auto Disarm
07 = Display "Reminder"
10 = Display Custom Words
11 = Periodic Test Report
- 1 -
Tech Support
Updated 2/11/09

Advertisement

loading

Summary of Contents for Honeywell VISTA-20P

  • Page 1 Some events are reserved for the installer only. • VISTA-20P: Provides up to 32 schedules: 16 schedules for use by the end-user, 16 for use by the installer. • VISTA-15P: Provides up to 8 schedules: 4 schedules for use by the end user, 4 for use by the installer.
  • Page 2 Step-by-Step Setting the System Clock The next step in the process is to set the system clock. To do so enter installer code + [#] + [6] [3] while in normal operating mode. • ALL partitions must be disarmed before you can set the system clock. DISARMED At the Disarmed Ready to Arm Screen Enter Installer code # 63 READY TO ARM...

This manual is also suitable for:

Vista-15pVista-10p