ADEMCO VISTA-20P Series Quick Installation Manual

ADEMCO VISTA-20P Series Quick Installation Manual

Hide thumbs Also See for VISTA-20P Series:

Advertisement

FOR DOCUMENTATION AND ONLINE SUPPORT: http://www.security.honeywell.com/hsc/resources/MyWebTech
Mount the Control.
1. Mount the control cabinet to a sturdy wall in a clean, dry area, which is not readily accessible to the
general public, using fasteners or anchors (not supplied) with the four cabinet mounting holes.
2. Remove cabinet door, then remove the lock
knockout from the door. Insert the key into the lock
CHECK
POSITION
3. Position the lock in the hole, making certain that the
LOCKED
latch will make contact with the latch bracket when
the door is closed. When correctly positioned, push
the lock until the snap tabs hold it securely.
The cabinet can be secured without a lock by
using 2 screws in the cover' s edge.
CABINET DOOR
4. Before installing the cabinet' s contents, remove
the cabinet knockouts needed for wiring entry.
Installing the Cabinet Lock
5. Mount the PC Board. Refer to the diagram below. If mounting an RF Receiver inside the cabinet,
remove the receiver board from its case, then insert the top of the board into the slots at the top of the
cabinet. Install the control board below the receiver board using the clips and screws provided. Insert
grounding lugs into the left-hand terminals of the antenna blocks and secure them with the screws
provided. Insert the receiver' s antennas into the blocks' right-hand terminals, and tighten the screws.
CIRCUIT
BOARD
CABINET
+
+
DETAIL A
SIDE VIEW
OF BOARD SUPPORTING
SLOTS
INSERT THE TOP OF THE
(PROVIDED) ON THE RAISED CABINET TABS.
CIRCUIT BOARD INTO THE
SLOTS AT THE TOP OF THE
CABINET
Mounting the PC Board
Connect the Transformer & Battery.
1321 Transformer (1321CN in Canada)
• Do not plug the transformer into the AC outlet until all wiring connections to the control are complete. As
a safety precaution, always power down the control when making such connections.
1361X10 Transformer
(required if using Powerline Carrier devices)
1. Splice one end of a 3-conductor cable to the wire ends of the SA4120XM-1 cable.
2. Connect the SA4120XM-1 cable plug to the 8-pin connector on the control.
3. Connect the other end of the 3-conductor cable to the 1361X10 Transformer.
Canadian Installations: For Powerline Carrier Devices, use the PSC04 X-10 Interface and trigger pins.
Battery Connections
• After all connections to the control are completed and after AC power has been applied, connect the
red and black flying leads on the control board to the battery.
• IMPORTANT: This control will not power-up on battery alone (AC power must be applied). However,
once the system is powered up, it will operate on battery if AC is lost.
UL For UL installations and Residential fire installations, refer to the chart below for the correct battery
size required to meet the mandatory standby time.
CALIFORNIA STATE FIRE MARSHALL (CSFM) AND UL RESIDENTIAL FIRE
24-HOUR BATTERY BACKUP REQUIREMENTS
The California State Fire Marshal and UL have regulations which require that all residential fire alarm
control panels must be provided with a backup battery which has sufficient capacity to operate the panel
and its attached peripheral devices for 24 hours in the intended standby condition, followed by at least 4
minutes in the intended fire alarm signaling condition. This control panel can meet these requirements
without using a supplementary power supply, provided that the panel's auxiliary power and bell output
currents are limited as listed below.
OUTPUT LIMITATIONS AND REQUIRED BATTERIES
OUTPUT CURRENT LIMITS
BATTERY INFORMATION
Current Total
Max. Aux.
Battery Capacity
Recommended Battery
Current
(Amp/Hrs)
(Yuasa Model No.)
600mA
45mA
4AH
NP4-12 (or ADEMCO 467)
maximum total
160mA
7AH
NP7-12
of auxiliary
200mA
8AH
NP4-12 (two) ‡
power plus bell
425mA
14AH
NP7-12 (two) ‡
output currents
500mA
17.2AH
NPG18-12
NOTE: Use two batteries, connected in parallel. Obtain an Ademco Battery Harness Kit SA5140-1. (Both batteries will
fit inside the cabinet.)
K5305-1QGV1 5/09 Rev. A
Connect Devices, Zones, Sounder, and Phone Line.
Refer to the Wiring Diagram on the reverse side for connection information. NOTE: This system uses a range of reserved addresses for each type of device.
1. Connect keypads and other addressable devices to the ECP terminals 4-7.
Refer to the wiring chart below for wire sizes and maximum wire run lengths.
PUSH
ON LOCK
UNTIL IT
Wire Chart For Devices Drawing Aux Power From The Control (12V+ & 12V–)
SNAP
IS SEATED
TAB
SECURELY
Wire
TOTAL CURRENT OF ALL DEVICES CONNECTED TO A SINGLE WIRE RUN
PUSH
Size 50 mA or less
#22
900ft (274m)
#20
1400ft (427m)
SNAP
TAB
#18
1500ft (457m)
UNLOCKED
#16
1500ft (457m)
BOTTOM
STEP 1
STEP 2
The length of all wire runs for both partitions combined must not exceed 1500 feet (457m) when unshielded quad
conductor cable is used (750 feet if shielded cable is used).
Standard Keypads (6150 / 6160 series)
• Keypad addresses range from address 16-23. Set each keypad's address accordingly.
NOTE: Address 16 is reserved for the first keypad and is always enabled in the control.
• Use data fields ∗190-∗196 to enable keypads and set their sounding options.
Expander Modules (4219, 4229)
• Connect desired field wiring to the module's zone terminals.
CIRCUIT
CABINET
BOARD
• Expander module addresses range from 07-11. Set each module's DIP address accordingly.
• Use ∗56 Menu mode to program zone characteristics.
Touchscreen Keypads (6270 / 6271 series, 8132 series; V20P = up to 4; V15P = up to 2)
DETAIL B
SIDE VIEW
• Use of touchscreen keypads is independent from and in addition to the eight (8) standard keypads.
OF MOUNTING CLIPS
• Set each touchscreen's address accordingly (1, 2, 5, 6; see table on back) and enable in field ∗189.
HANG TWO SHORT MOUNTING CLIPS
• Make sure the auxiliary current drain is within the control's limitation. Otherwise use an external
SECURE THE BOARD TO THE
CABINET WITH THE ACCOMPANYING
power supply to power the touchscreen keypads.
SCREWS
cb_mount-001-V1
RF Receiver (5881, 5883, RF Keypad)
• 5881L / 5882L = up to 8 RF zones; 5881M / 5882M / 6150RF = up to 16 RF zones
5881H / 5882H / 5883 / 6160RF = up to system maximum RF zones
• Set the receiver's address to 00 using the module's DIP switches.
• If using wireless keypads, set field ∗24 RF House ID Code appropriately.
If receiver is mounted remotely, note the following:
• Do not locate the receiver or transmitters on or near metal objects. This will decrease range and/or
block transmissions.
• Do not locate the RF receiver in an area of high RF interference (indicated by frequent or
prolonged lighting of the receiver's LED; random flicker is OK).
• Do not locate RF receiver closer than 10 feet from any keypads.
Program the Control.
Refer to the Programming Guide to program the control.
(
The control can also be programmed via the Compass Downloader.)
1. Enter Programming Mode: installer code + 8-0-0.
2. Change the default Installer Code using field ∗20.
3. Enter the appropriate central station phone numbers and account numbers.
4. Program the system data field options as desired.
4. Use the various menu modes to program zones, relay outputs, descriptors, etc.
5. If AVS system is installed, use the appropriate AVS Quick Program Command.
6. Program Schedules (if used): Master code + [#] + 64
7. Enable RF button keyfobs (if used) and assign to user numbers accordingly.
8. Show the Master user how to change the default Master code:
master code + [8] + 0-2 + new code + new code again
Test the System.
Sniffer Mode Test: To verify that all transmitters have been properly programmed, disarm all partitions.
1. From a keypad in partition 1, enter Installer code + [#] + 3. All programmed transmitters are displayed.
2. Fault all transmitters in turn. The display clears each transmitter as a signal is received.
3. Exit Sniffer mode: Installer code + 1 (OFF). Mode does not automatically expire; you must exit manually.
System Test
1. Disarm the system and close all protected windows, doors, etc.
2. Enter the Installer code + [5] (TEST), then press 0 = walk. (Option 1 = Dial checks phone line integrity.)
3. Listen. The external sounder should sound for about 1 second then turn off.
4. Fault all zones in turn and listen for three beeps from the keypad. ID of each faulted point should
appear on the keypad display. The display clears when the zone is restored.
5. Test all smoke and CO detectors following the manufacturer' s instructions and check the display.
6. When all zones have been checked and are intact (closed), there should be no zone identification
numbers displayed on the keypad.
7. Exit test mode: security code + [1] (OFF).
(see instructions K5305-1V7 or higher)
100 mA
300 mA
500 mA
600 mA
450ft (137m)
150ft (46m)
90ft (27m)
75ft (23m)
700ft (213m)
240ft (73m)
140ft (43m)
120ft (37m)
1100ft (335m)
350ft (107m)
220ft (67m)
170ft (52m)
1500ft (457m)
550ft (168m)
350ft (107m)
270ft (82m)
These instructions apply to the following Honeywell security systems:
ADEMCO VISTA-20P, VISTA-20PSIA, VISTA-20PCN, VISTA-15P, VISTA-15PSIA, VISTA-15PCN
Features and procedures apply to all, except where differences are noted.
VISTA-20PSIA and VISTA-15PSIA are certified SIA-compliant controls that meet SIA specifications for
False Alarm Reduction.
Relay Modules (4204)
• Connect desired field wiring to the module's relay contact terminals.
• Relay module addresses range from address 12-15.Set each module's DIP address accordingly.
• Use ∗79 / ∗80 Menu modes to map each device address and define output functions.
Communication Device (7847i, 7845GSM, 7845i-GSM, GSMV)
• Set the communication device to address 03.
• Use ∗29 Menu mode to enable and program the device.
AVS System
• If used, follow the installation instructions provided with the module.
• Connect the AVS module to the control's ECP terminals and connect all other ECP devices to the
AVS module's ECP terminals.
• Set the AVS address using its DIP switches: V15P = 08; V20P = 11
• Use the desired AVS Quick Program Command to set pre-defined options:
installer code + [#] + 0 + 3: enable AVS operation
installer code + [#] + 0 + 4: enable AVS and enable panel sounds on AVST speaker
• Use field ∗55 Dynamic Signaling Priority to select the desired reporting paths.
2. Connect hardwire zones to the appropriate zone terminals 8-20.
3. On-Board Trigger Connections
• Connect field wiring to the appropriate trigger pin using the SA4120XM-1 cable (if using 1361X10
transformer) or the 4-wire cable supplied (N4632-4).
• Trigger outputs are normally high, and go low upon programmed condition (can be set inverted).
• Use ∗79/∗80 Menu modes to program the trigger outputs.
• Output 17 (pin 1) = supports up to 100mA max; Output 18 (pin 5) = supports up to 20mA max
4. Install Wireless Zone Transmitters.
• Use ∗56 Menu mode to program wireless zones and enroll the transmitters.
• Use the Go/No Go Test mode to verify adequate signal strength from each transmitter location:
Enter Installer code + [#] + 4, then fault each transmitter and listen for 3 beeps at the keypad and
the zone display. Exit mode: user code + 1 (OFF).
5. Connect the external sounder to terminals 3 and 4.
• If supervised output desired, see Sounder Supervision wiring diagram on reverse side, and set field
∗91 Option Selection for Bell Supervision.
6. Connect the phone line using terminals 21-24.
• Use an RJ31X jack as shown in the diagram on reverse side.
Major Features and Capacities
Feature
VISTA-20P
Partitions
2 plus common area
Zones
48 plus 16 keyfob zones for
total of 64 zones:
• 8 hardwired zones (1-8)
• Up to 40 additional wired
zones (9-48) using up to 5
4219/4229 modules
• Up to 40 wireless zones
(5800 series; zones 9-48)
• 4 configurable zone types
Security Codes
48
Schedules
32
Keypad macros
4
Event Logging
100
Paging
4
Keypads
8
Touch Screen Devices
4
4219, 4229
5
4204
4
Output Relays / X-10 devices
16
On-Board Triggers
2
Output Functions
48
WARRANTY INFORMATION
For the latest warranty information, please go to:
www.honeywell.com/security/hsc/resources/wa
VISTA-15P
not partitioned
32 zones plus 8 keyfob zones
for total of 40 zones:
• 6 hardwired zones (1-6)
• Up to 16 additional wired
zones (9-24) using up to 2
4219/4229 modules
• Up to 26 wireless zones
(5800 series; zones 9-34)
• 2 configurable zone types
32
8
2
50
2
8
2
2
2
8
2
24
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright © 2009 Honeywell International Inc.
www.honeywell.com/security

Advertisement

loading

Summary of Contents for ADEMCO VISTA-20P Series

  • Page 1 WARRANTY INFORMATION ‡ NOTE: Use two batteries, connected in parallel. Obtain an Ademco Battery Harness Kit SA5140-1. (Both batteries will 6. When all zones have been checked and are intact (closed), there should be no zone identification fit inside the cabinet.) For the latest warranty information, please go to: numbers displayed on the keypad.
  • Page 2 DETECTORS METAL COLD WATER PIPE: USE A NON-CORROSIVE METAL STRAP (16 MAX) OR CAN USE ADEMCO No. 702 SIREN, OR 12V BELL. (COPPER IS RECOMMENDED) FIRMLY SECURED TO THE PIPE TO WHICH STANDARD THE GROUND LEAD IS ELECTRICALLY CONNECTED AND SECURED.

This manual is also suitable for:

Vista-15p seriesAdemco vista-20p seriesAdemco vista-15p seriesAdemco vista-20pAdemco vista-20psiaAdemco vista-20ppcn ... Show all