Installation and Setup Guide

Compatible Devices

Device
Addressable Keypads
Touch Screen (AUI)
Devices
4219, 4229 Zone
Expander Modules
5800 Series Wireless
Output relays and/or
Powerline Carrier
Devices (X-10 type)
On-Board Triggers
Output functions
4286 Phone Module
Audio Alarm
Verification
Alarm output
Auxiliary Power Output
Backup Battery
Internet Connection
and Optional VISTA-
GSM4G Module
AC Power Supply
NOTE: All devices and accessories used in a Canadian installation must be Listed for use in Canada.

Important Installation Highlights (Installer Please Read)

• This system uses addressable keypads and Zone Expander Modules (see Table of Addresses
in Section 2. Mounting and Wiring – Connecting the Keypads and Other
Addressable Devices).
• Keypads must be set for addresses 16-23 (first keypad is address 16, which is different
from previous controls) and programmed in data fields *190-*196.
• Zone Expander Modules must be set for specific addresses (07-11), based on the zone
numbers used.
• 4204 Relay Modules must be set for specific addresses (12-15).
• This control will not power-up unless AC power is connected (will not power-up on battery
alone). However, once the system is powered up, it will operate on battery power in the
event of AC loss.
• Relays have two programming menu modes: Use *79 Menu mode to map module addresses
and device (output) numbers. Use *80 Menu mode to define the output functions.
• This system supports programmable function keys. Use *57 Menu mode to define the
function keys.
• This system provides various paging features. Refer to the Programming Overview
section for a summary on pager programming.
1-2
Limits
8
6150 Fixed-Word Keypad, 6160 Alpha Keypad, 6150V Fixed-Word
Display Voice Keypad, 6160V Alpha Display Voice Keypad,
6150RF Keypad/Transceiver
4
Touch Screen (AUI) devices are in addition to the 8 addressable
keypads. E.g., 6272, 6280, Tuxedo
Up to 5 for
Zone numbers are predefined according to the device addresses
up to 40
used. See Expander Module Addresses table in Wiring section and
exp. zones
set addresses accordingly.
Up to 40 RF
Uses 5881/5883 Series Receivers/Transceivers.
zones
Up to 16
Use any combination of 4204, 4229 and or Powerline Carrier
Devices.
Map output devices via *79 Menu mode.
2
Can be used to reset 4-wire smoke detectors.
Up to 48
Program output functions via *80 Menu mode.
Partition 1
Provides access to the system via on premises or off-premises
only
phones for arming, disarming, etc., plus control of relay outputs
and Powerline Carrier devices.
Using AAV
Honeywell AVS system can be used to permit voice dialog between
module
an operator at the central station and a person at the premises via
phone line
12VDC, 2
Can drive the compatible sounders; steady output for
AMP output
burglary/panic, or temporal pulse (3 pulses – pause – 3 pulses –
pause – 3 pulses. . .) for fire. Uses current limiting circuitry for
protection.
See note.
12VDC, 600 mA maximum; uses circuit protection.
See note.
Rechargeable (sealed lead-acid type) 12VDC, 4AH minimum.
See note.
Internet connection is made via an on-board Ethernet connector
for high speed (broadband) hardwire connections, and/or use of
the optional on-board VISTA-GSM4G module.
See note.
Plug-in 120VAC transformer, ADEMCO 1361 (1361CN in
Canada) or, if using Powerline Carrier devices, ADEMCO
1361X10 Transformer Module
Notes