System Status Report Codes

Zone report codes are programmed using interactive ✱ 56
or ✱ 58 Zone Programming modes, while system status
(non-alarm) codes and restore codes are entered in data
fields *59 - *68, *70 - *76, *89. The actual report code
digits that you enter depend upon the particular
installation, and should agree with the Central Station
office receiving the signals.
3+1 or 4+1 Standard Format: Enter a code in the
first box: 1–9, A, B, C, D, E, or F. Enter #+10 for A (this
reports a 0 on some receivers), #+11 for B, #+12 for C,
#+13 for D, #+14 for E, #+15 for F.
An entry of 0 in the first box disables a report. Entering
0 in the second box advance to the next field.
Expanded or 4+2 Format: Enter codes in both boxes
(first/second digits) for 1–9 or A–F, as described above.
A 0 in the first box disables a report. A 0 in the second
box eliminates the expanded message for that report.
ADEMCO Contact ID® Reporting: Enter a digit in
the first box to enable the zone to report. Use a different
digit for each zone until you have used up available
digits. If the number of zones exceeds the number of
available digits, begin with digit 1 again. This is an
"enabling" code only and is not the actual code sent to
the Central Station office. Entries in the second boxes
are ignored. An entry of 0 in the first box disables the
report.
U L
Report codes are required in fields *61, *65, *71, *72, for
UL Commercial Burglar Alarm installations.
Report codes are required in fields *60, *62, *63, *64, *70, *73,
*74, *75, *76, for UL Commercial Burglar Alarm installations and
required for Residential Fire Alarm installations.
*59
Exit Error Report Code
0 = no report; 1-F = see description above
V21iPSIA:
[1] Always enabled. Also see field *69.
After arming the system, entry/exit and interior zones
remaining open after exit delay expires cause an alarm
sound at the keypad and external sounder (keypad also
displays "EXIT ALARM"), and entry delay begins.
Disarming before the end of the entry delay stops the
alarm sounding and no message is sent to the central
station. The keypad will display "CA" (fixed-word) or
"ALARM CANCELED" (alpha display).
If the system is not disarmed before entry delay expires,
an "EXIT ALARM" message
message) will be sent to the central station. The keypad
will display "EA" (fixed-word ) or "EXIT ALARM" (alpha
display), and alarm sounding continues until the system
is disarmed (or timeout occurs).
An Exit Alarm condition will also result if a fault occurs
in an exit or interior zone within 2 minutes following the
end of the exit delay, and an "EXIT ALARM" message
will be sent to the central station (except for V21iPSIA,
see field *69 Recent Closing report).
format, the message will contain the zone number
and error code 374 ("ALARM–EXIT ERROR").
4-4
(V21iPSIA:
also zone alarm
With Contact ID
*60
Trouble Report Code
(0 = no report; 1-F = see description above *59
Sent if a zone has a trouble condition. See UL System
Reporting Note above *59.
*61
Bypass Report Code
0 = no report; 1-F = see description above *59
Sent when a zone is manually bypassed. See UL System
Reporting Note above *59.
*62
AC Loss Report Code
0 = no report; 1-F = see description above *59
Timing of this report is random with up to a 4-hour
delay. If AC restores before the report goes out, there is
no "AC LOSS" report. See UL System Reporting Note
above *59.
*63
Low Bat Report Code
0 = no report; 1-F = see description above *59
Sent when the system's backup battery has a low-battery
condition. See UL System Reporting Note above *59.
*64
Test Report Code
0 = no report; 1-F = see description above *59
Sent periodically to test that the communicator and
phone lines are operational. See System Reporting UL
Note above *59. Frequency of report is set in Scheduling
mode (event 11) or by the following key commands:
installer code + [#] + 0 + 0 = test report sent every 24 hrs
installer code + [#] + 0 + 1 = test report sent once per week
installer code + [#] + 0 + 2 = test report sent every 28 days
Each of these modes sets schedule 32 to the selected
repeat option; first test report sent 12 hours after
command†.
† NOTE: Make sure the Real-Time Clock is set to the proper
time before entering the test report schedule command to
ensure that test reports are sent when expected. (see Setting
the Real-Time Clock section)
*65
Open Report Code
0 = no report; 1-F = see description above *59
Sent upon disarming the system in the selected
partitions. See UL System Reporting Note above *59.
*66
Arm Away/Stay Report Code
0 = no report; 1-F = see description above *59
This option allows for independent programming of
Away and Stay reports for each partition, including the
common lobby.
NOTE: "OPEN" reports are not sent if the associated
closing report is not enabled.
*67
RF Trans. Low Batt. Report Code
0 = no report; 1-F = see description above *59
Sent when a transmitter low-battery condition exists.
UL installations: must be enabled if wireless devices
are used.
*68
Cancel Report Code
0 = no report; 1-F = see description above *59
Sent upon disarming the system after an alarm
condition was reported.
V21iPSIA: