Field Replaceable Front Panel; Replace Front Panel - Honeywell THOR VM2 Reference Manual

Vechicle-mounted computer
Hide thumbs Also See for THOR VM2:
Table of Contents

Advertisement

Field Replaceable Front Panel

Equipment Required - User Supplied:
Torquing tool capable of measuring inch pounds
l
#2 Philips screwdriver bit
l
Caution
Before replacing the Thor VM2 front panel, the internal
The front panel of the Thor VM2 is field replaceable. The front panel assembly contains the integrated keypad and touch
screen. Should either of these components fail, the front panel assembly can easily be replaced to reduce downtime.

Replace Front Panel

1. Place the Thor VM2 on a clean, well-lit surface before performing the front panel replacement.
2. Shutdown the Thor VM2 from the Windows menu.
3. Remove the Thor VM2 from the Quick Mount Smart Dock.
4.
Disconnect the
UPS.
5. Loosen the twelve (12) captive M3 screws holding the front panel. Use a #2 Philips bit.
5. Carefully lift the front panel away from the device.
UPS battery must be
disconnected.