Auto-On; Thor Vm2 Is Off; Thor Vm2 Is On - Honeywell THOR VM2 Reference Manual

Vechicle-mounted computer
Hide thumbs Also See for THOR VM2:
Table of Contents

Advertisement

Auto-On

Select the Auto-On power scheme when it is desired that the Thor VM2 power on when external power is connected.
In Auto-On mode, the Thor VM2 is turned On by the presence of external power with no user interaction required. Ignition input
is ignored when Auto-On Mode is enabled.
The following default timeouts are used in the Auto-On power scheme.
Plugged In
Setting
(AC or DC
Turn off monitor
30 minutes
Turn of hard disks
30 minutes
System standby
System hibernate
When the Auto-On Power Scheme is selected and external power is present the Thor VM2 behaves as described below. If
external power is not present, refer to the

Thor VM2 is Off

Conditions
The Thor VM2 is Off and gets external power, such as
Thor VM2 is installed on a powered Quick Mount Smart Dock with the Dock power switch On
l
Thor VM2 is already mounted to a Dock and external power is applied to the Dock
l
Thor VM2 is already mounted to a Dock and the Dock power switch is turned On
l
Result
The Thor VM2 boots. Once booted the Thor VM2 follows the Auto-On power scheme with timers reset after the boot
completes.

Thor VM2 is On

Conditions
The Thor VM2 is On and gets external power, such as
Thor VM2 is installed on a powered Quick Mount Smart Dock with the Dock power switch On
l
Thor VM2 is already mounted to a Dock and external power is applied to the Dock
l
Thor VM2 is already mounted to a Dock and the Dock power switch is turned On
l
Result
The Thor VM2 continues to run and follows Auto-On power scheme with timers reset at the time power was connected.
Running on
Batteries
Power)
(UPS Power)
1 minute
1 minute
5 hours
10 minutes
Never
20 minutes
UPS
section for Thor VM2 behavior.
3-30