Disconnect Ups Battery - Honeywell THOR VM2 Reference Manual

Vechicle-mounted computer
Hide thumbs Also See for THOR VM2:
Table of Contents

Advertisement

Disconnect UPS Battery

Equipment Required- User Supplied:
Torquing tool capable of measuring inch pounds
l
#2 Philips screwdriver bit
l
Caution
The UPS battery must be disconnected before shipping the Thor VM2 or
1. For convenience, the Thor VM2 can be removed from the Quick Mount Vehicle Dock, though it is not necessary.
2. If the Thor VM2 remains in the Dock, disconnect the power cable from the Dock.
3. Shutdown the Thor VM2.
4. Place the Thor VM2 face down on a stable surface.
5. Using a #2 Philips bit loosen the M3 screws and then remove the tethered access panel with the SIM label. This panel is
on the right hand side when the Thor VM2 is face down with the top away from the user.
6. Locate the small push button located just below the SIM card installation slot.
replacing the front
panel.
2-31

Advertisement

Table of Contents
loading