Table 5-18 NI-2 Card Redundancy Alarms (continued)
Alarm
Peer APS mode mismatch
Both units ACTIVE
Table 5-19

Table 5-19 Fan Tray Alarms

Alarm
Not detected or missing
Multiple fan failures
Single fan failure
Table 5-20

Table 5-20 Power Alarms

Alarm
Input voltage out of range
Excessive current
Fan voltage out of range
Power supply fault
Temperature exceeds limit
OL-2365-01
Keyword
Severity
APS_MODE_MISMAT
Minor
CH_ALARM
NI2_RF_ACTIVE_CL
Info
ASH
describes fan tray alarms.
Severity
Major
Major
Minor
describes power alarms.
Severity
Major
Major
Major
Major
Major
Description
The OC-3 trunk is connected to a device not
configured for nonrevertive, unidirectional APS.
Both the primary and the secondary NI-2 cards have
come up in an active state.
Description
The fan tray has been removed from the chassis or
is missing.
Two or more fan modules in the fan tray have failed. When
fan modules fail, the remaining fan modules run at full
speed until the fault is corrected.
One of the three fans in the fan tray has failed. When fans
fail, the remaining fans run at full speed until the fault
is corrected.
Description
The input voltage to one or both PEMs is outside the
acceptable range.
The current flowing through one or both PEMs is
too high.
The voltage going to the fans from one or both PEMs is
outside the acceptable range.
One or both PEMs are reporting a fault caused by high
temperature, output failure, or input failure.
The PEM temperature is beyond the acceptable range.