6.
1 MAINTENANCt
the base plate locking screws and turn the
base plate until the
correct ignition timing is
obtained for the R/H
cylinder.
21
Move
the
L/H contact breaker plate within
the range where th L/H correct point gap
in
maintained.
Repeat the operation outlines in pars.
11 and
21 until the correct
ignition
timing is obtained
for both
L/
H and R/H cylinders.
If the correct
ignition timing is not obtained for either L/H or
~/H cylinder within the point gap range of cor-
rect
gap, replace the contact
breaker point
asse
mbly with a new one and make a
readjust-
ment.
NOTE:
• Mc
ke sure to turn the rotor counterclockwise.
Do not reverse the rotor.
• It
is
advisable that L/H and R/H contact point
gap
be idenHcal in setting.