Technical Specifications - Honeywell Satellite XT 9602-0400 FTT Manual To Operation

Table of Contents

Advertisement

9.8

Technical Specifications

Power Requirements
Voltage
Consumption
Physical Dimensions
Size
Weight
Housing Protection Class
RFI / EMC
Operating Conditions
Sample tubing
Response time
Temperature
Pressure
Humidity
Maximum negative pressure (at
pump)
Maximum sample line length
Recommended sample
line length
Part Number
version for toxic/corrosive gases
(except C 5 F 8 and SF 6 )
version for combustible gases
version for C 5 F 8 and SF 6
Warning:
Extractive Module 20404-0200 must only be used with Pyrolyzer
Modules 20408-0110, 20408-0112, 20408-0116 and 20408-0122.
Extractive Module 20404-0300 must only be used with Pyrolyzer
Modules 20408-0114 and 20408-0120.
Satellite XT FTT Versions
power is provided by the Satellite XT,
power supply range 18 - 24 VDC
max. 2.4 W
78 x 95,5 x 50 mm
3,1" x 3,8" x 2,0"
500 g
17.6 oz
IP 30
EN 50270
OD 1/4" ID 3/16" PTFE or PFA
< 30 sec. with a tubing length of 10m
0 °C ... +40 °C
+32 °F ... +104 °F
700 ... 1300 hPа
20 ... 90 % r.h.
-150mbar
50 m (see note in section 9.6)
10 m
20404-0200
20404-0250
20404-0300
Extractive Module XT - Section 9
(W x H x D)
(W x H x D)
9-6