2.5

Relay Wiring

Instruments with relay option have an additional
6–wire shielded cable extending from the bottom of the instrument. This cable has a length of 3 meters
and is also permanently attached to the instrument.
The 6-wire shielded cable is used for relay wiring and provides a pair of connections for each of the 3
internal relays for activation of visual or audible external alarm devices.
Relay Contacts
1
white
Alarm 1 Relay
1
brown
Alarm 1 Relay
2
green
Alarm 2 Relay
2
yellow
Alarm 2 Relay
3
grey
Fault Relay
3
pink
Fault Relay
S
shield
cable shield
Junction Box 1 node, R-version for instruments with relay option.
! Note:
All wiring for the Satellite XT and its related equipment must be in compliance with
any local electrical and fire codes. The Satellite XT wiring must be kept away from
any high power lines. All shielding for the wiring must be connected together and
grounded at only one point in the system.
Satellite XT FTT Versions
165
120
P+
P+
P-
P-
N+
N+
N-
N-
S
S
P+
P+
P-
P-
N+
N+
N-
N-
S
S
180
Installation and Start-Up - Section 2
D
D
1/A1 1/A1 2/A2 2/A2
3
F /
3
F /
D
D
1/A1 1/A1 2/A2 2/A2
3
F /
3
F /