SPECIFICATIONS

Power supply
Outputs
Operating Temperature
Media Compatibility
Zero adjustment
Sensor type
PWTB Transmitter
(2)
Accuracy
Range
according to PSID table in
PWTB Transmitter DIP
Switch Configuration table
Sensor Performance
Enclosure, PWTB
Enclosure, Sensor
1
One side of transformer secondary is connected to signal common. A dedicated transformer is recommended.
2
Because of lower accuracy, it is not factory recommended to use an output range less than 10% of the total sensor PSIG.
The material in this document is for information purposes only. The content and the product described are subject to change without notice.
Honeywell makes no representations or warranties with respect to this document. In no event shall Honeywell be liable for technical or editorial
omissions or mistakes in this document, nor shall it be liable for any damages, direct or incidental, arising out of or related to the use of this
document. No part of this document may be reproduced in any form or by any means without prior written permission from Honeywell.
Honeywell Building Technologies
715 Peachtree St NE
Atlanta, Georgia 30308
customer.honeywell.com
buildings.honeywell.com
Table 4. Specification Details
Voltage output (0-5V)
Voltage mode (0-10v)
Current mode (4-20mA)
Switch selectable
Transmitter
Type
Temperature
Automatic
Micro-machined silicon strain gauge
Sensor
PWTB50
PWTB100
PWTB250
PWTB50
PWTB100
PWTB250
Accuracy
Stability (1 year)
Over-range protection
Pressure Cycles
Compensated Range
Temperature
Compensation %FS/C
Vibration
Construction
Rating
Construction
® U.S. Registered Trademark
©2022 Honeywell International Inc.
31-00539-01I Rev. 05-22
(1)
12-30 VDC/24 VAC
, 20 mA max.
13-30 VDC/24 VAC required for 10V FS output
15-30VDC(0 ohm)/16-30VDC (250 Ohm) / 18-30VDC (500 Ohm),
20mA max
2-wire 4-20 mA, 3-wire 0-5V/10V
-22 to 158 °F (-30 to 70 °C)
Water, other 316 SS compatible media (316L diaphragm)
32 to 250 °F (0 to 125 °C)
Pushbutton, Remote zero
Press the button for 5 seconds to re-zero
Hold for 10 seconds to restore factory settings
1% Accurate ranges
20/25/30/40/50 PSID
138/172/207/276/345 kPa
40/50/75/100 PSID
276/345/517/689 kPa
75/100/125/150/250 PSID
517/689/862/1034/1724 kPa
2% Accurate ranges
10/15 PSID
69/103 kPa
15/20/25/30 PSID
103/138/172/207 kPa
30/40/50 PSID
207/276/345 kPa
< +/-0.25% BFSL
+/-0.2% FS, typ
200 % rated pressure
> 100 million
14 to 158 °F (-10 to 70°C)
Zero, <±0.03 (<100 kPa), <±0.02(>100 kPa)
Span, <±0.03 (<100 kPa), <± 0.02(>100 kPa)
10G peak, 20 to 2000 Hz
PC/ABS
NEMA 4X
Stainless Steel, 304, 1/4" MNPT, PG9 Conduit Fitting