Servicing The Hard Disk Drives And Power Supply; Installing Hot Spare Hard Drive - Honeywell HP ProLiant DL360P Gen8 Service Manual

Table of Contents

Advertisement

5.4

Servicing the hard disk drives and power supply

The server from Honeywell is configured with five 146 GB SAS hard drives. Four are used in a RAID-5
configuration and the fifth hard drive is a hot spare. The configuration also contains a dual redundant
power supply. Both the hard disk drives and power supplies are hot swappable. You must, however,
remove and replace only one power supply or hard disk drive at a time. Ensure that this is done on a
system that is powered on. Refer to the HP documentation listed in the following table for detailed
instructions on swapping the power supply and hard disk drive.
Publication
HP ProLiant DL360 Gen8 Server Maintenance and
Service Guide
HP ProLiant DL360 Gen8 Server User Guide

Installing hot spare hard drive

l
5.4.1
Installing hot spare hard drive
You can insert the hot spare hard drive only when the server in on.
To insert the hot spare hard drive
1. From the front end of the server, locate the blocking plate.
2. Press the latches located at the ends of the blocking plate and pull the blocking plate as illustrated
below.
3. Remove the blocking plate.
Contains information on
Service and maintenance
Operation, setup,
troubleshooting
- 46 -
Chapter 5 - Servicing

Advertisement

Table of Contents
loading

Table of Contents