Installation Precautions; Installing The Sce 2000 On A Workbench Or Tabletop - Cisco SCE 2000 4xGBE Installation And Configuration Manual

Cisco systems sce 2000 platform installation and configuration guide
Table of Contents

Advertisement

Chapter 4
Installation and Maintenance

Installation Precautions

The router should already be in the area where you will install it, and your installation location
should already be determined. If not, see
Preparation and Safety Guide.
When installing the SCE 2000, please observe the following conditions:

Installing the SCE 2000 on a Workbench or Tabletop

You can install the SCE 2000 platform on any flat surface as long as the surface is large enough
for the SCE 2000 (see the table in SCE 2000 Dimensions), and allows for adequate
airflow/ventilation around the sides of the SCE 2000, as described in the
(on page 4-5). When installing the SCE 2000 on a workbench or tabletop or in a rack, ensure that
the surface is clean and in a safe location.
Figure 4-3: Installing the System on a Flat Surface
To install a SCE 2000 platform on a workbench or tabletop, complete the following steps:
Step 1
Remove any debris and dust from the tabletop or workbench, as well as the surrounding area.
Also make sure your path between the SCE 2000 platform and its new location is unobstructed.
Place the SCE 2000 platform on the tabletop or workbench.
Step 2
OL-7824-04
Allow at least 2 inches (5 cm) of clearance at its left and right sides for airflow clearance
from the inlet and exhaust vents, and that no exhaust air from other equipment is drawn into
the SCE 2000. For descriptions and illustrations regarding airflow, see
3).
Do not place the SCE 2000 on the floor during installation. Dust that accumulates on the
floor is drawn into the interior of the SCE 2000 by the cooling fans. Excessive dust inside
the SCE 2000 can cause over-temperature conditions and component failures.
Allow at least 5 inches (12.7 cm) of clearance at the front and rear of the SCE 2000 for
installing and rudimentary maintenance for accessing network cables or equipment.
Ensure that the SCE 2000 will receive adequate ventilation. Do not install the SCE 2000 in
an enclosed cabinet where ventilation is inadequate!
Provide an adequate chassis Ground (earth) connection for the SCE 2000 (see
Chassis Ground Connection
Site Requirement Guidelines
(on page 4-10) for instructions).
Cisco SCE 2000 4xGBE Installation and Configuration Guide
Installing the SCE 2000 Platform
(on page 4-3) and the Site
Airflow
(on page
Attaching a
Installation Precautions