Replacing the Chassis Cover
Figure B-19
Note
Note
Note
b.
Insert the safety ground (green wires) into the DC connector ground connector and tighten the
locking screw. Ensure that no bare wire is exposed.
c.
Insert the +48 VDC return wires into the DC connectors (+) and tighten the locking screws. Ensure
that no bare wire is exposed.
d.
Insert the –48 VDC wires into the DC negative connectors (–) and tighten the locking screws. Ensure
that no bare wire is exposed.
Cisco AS5350XM Universal Gateway Chassis Installation Guide
B-14
Connecting DC Power Supply—Redundant Power Supply
To DC source
DC connector
A - A + B - B +
Source A - NEG
Source A - RTN
This product is intended for installation in restricted access areas and is approved for connection
using 12 or 14 AWG copper conductors only. The installation must comply with all applicable
codes.
For central office installations, we recommend using a 6 AWG green ground wire with one end
connected to reliable earth. The other end of the wire should be crimped onto the double-hole
lug provided in the installation pack. The lug should be secured to the mating holes on the side
of the chassis with the two screws included in the accessory pack.
If you are installing a redundant power supply, you should attach appropriate-sized spade
terminals to the stripped ends of the ground and input wires.
Ground
Source B - RTN
Source B - NEG