B
Example String: = CUW 0/901000220/ (Space after cuw, category and each
Where the first 0 reflects the string version, the next number is the number of
categories and the remaining numbers before the second separator reflect the
ID for each of the categories.
String breakdown Explanations:
CUW = The command to write
0
= String Version
/
= Separator
9
= the number of categories
0
= Category #1 ID = 0
1
= Category #2 ID = 1
0
= Category #3 ID = 0
0
= Category #4 ID = 0
0
= Category #5 ID = 0
0
= Category #6 ID = 0
2
= Category #7 ID = 2
2
= Category #8 ID = 2
0
= Category #9 ID = 0
/
= Separator
4.2.3.4 EGPWS RS-232 Maintenance Port (port: SMC1)
One port is provided which meets the characteristics specified in RS232C. This bus can
be used to access internal data from the EGPWS for aircraft testing. In addition to the
internal data, other items such as unit configuration and flight history can also be
accessed.
Baud Rate
Parity
Data Bits
Stop Bits
Maximum Recommended Cable Length
Pin Assignment (Signal Mnemonic)
RS-232TXD_MON
RS-232RXD_MON
Rev 0, October/2000
number if there is no separator)
(TSO-C151a Class B curve set)
(Altitude Encoder with 500 ohm
(GPS, Internal GPS Express RS-232)
(Display select = ASPB)
(I/O Discrete Type Select = Basic, Lamp
(Audio Menu Select = Basic)
(Audio Output Level = -12dB)
(Altitude Monitor Option Select = Disable)
(TA&D Alternate Pop Up = False)
10609I00.ZIPCDL
KMH 880/KTA 870
Temperature Probe)
format 2)
19,200
none
8
1
15 meters
J10-99
J10-100
Page 4-3