Continued from the previous page.
5. Apply leak test solution to the fittings.
6. Re-install the LP mounting bracket.
7. Re-install the LP cylinder on the tank mount, fasten the clamps, and re-connect
the fuel supply hose to the discharge valve.
8. Slowly rotate the knob on the discharge valve counterclockwise until the valve is
fully open.
9. Watch and listen carefully for indications of leaking LP. If there are no leaks,
start the engine and run it for a few minutes to make sure that LP is flowing
smoothly.
The LP lockoff / filter cartridge has now been replaced.
5.20

Cleaning the Machine

When
Clean the machine after each use.
Overview
Regular cleaning is essential for keeping the trowel in serviceable condition. It is
important to remove uncured concrete, dust and dirt from the trowel as soon as
possible after work has been completed.
Requirements
Engine stopped and machine cool to the touch
Fresh, clean water supply
Pressure washer
Clean, soft cloths
Procedure
Perform the procedure below to clean the machine.
1. Use a pressure washer to remove concrete and debris from the trowel blades
and ring guards.
2. Keeping a minimum distance of 1 meter (3 feet) away, use the pressure washer
to rinse the trowel body.
NOTICE: Direct, high water pressure at close range will damage certain
components on the machine. The following components should be wiped clean by
hand using a damp, clean cloth. Do not apply high pressure spray to these
components:
Operator's station including the seat, control switches, key switch, and indicator
lights.
Electrical connectors
wc_tx002046gb.fm