Continued from the previous page.
3. Disconnect and remove the LP tank from the LP mounting bracket (c).
4. Remove the LP mounting bracket, keeping the clamps (d) attached.
5. Loosen the P-clips (e) holding the LP hoses.
6. Disconnect the wiring harness (f) from the LP lockoff / filter cartridge.
7. Unscrew and remove the LP lockoff / filter cartridge from the fuel supply hose.
Installing the
1. Clean the fittings (g) to remove residual thread sealant. Apply a fresh coat of
replacement
thread sealant.
cartridge
2. Install the replacement LP lockoff / filter cartridge. Tighten by hand, and then
use a wrench to rotate the cartridge an additional 2–3 turns.
3. Re-install the P-clips. Make sure the in-line relief valve (h) is oriented as shown.
4. Re-connect the wiring harness, making sure that the connectors (i) are fully
engaged.
h
This procedure continues on the next page.
c
d
i
g