CRT 48-33K
4.12
Before Starting
Requirement
Operator must be familiar with the location and function of all controls.
Checklist
Check the following items before starting the trowel:
fuel level—add fuel as needed
oil level in the engine—add oil as needed
air filter—element is clean and undamaged
trowel arms and blades—functional and undamaged
wiring and electrical connections—check every 50 hours
4.13
Starting the Machine
Requirements
Fuel change switch in the correct position (LPG or gasoline)
Choke closed (only if running the engine on gasoline)
Note: Do not use the choke if running the engine on LPG.
Procedure
Perform the procedure below to start the machine.
1. Sit in the operator's seat.
2. Turn the engine key switch (o) clockwise and hold it until the engine starts.
3. Allow the engine to idle for 5 minutes.
You may now begin operating the trowel.
NOTICE: Cranking the engine for more than five seconds can cause starter
damage.
If the engine fails to start, release the key switch and wait 10 seconds before
operating the starter again.
If the engine still will not start after multiple attempts, see Troubleshooting.
wc_tx002045gb.fm
o
43
Operation
wc_gr010113