Maintenance
5.12
Replacing the Drive Belt
Procedure
To replace the drive belt, do the following steps.
1. Place the trowel on a flat, level surface with the blades pitched flat.
2. Disconnect battery.
3. Remove the beltguard.
4. Remove the 3 bolts (a) holding the universal joint (b) to the drive pulley.
5. Remove the old belt and install a new one.
6. Reverse the procedure for assembly. Align the bearings and shaft as straight as
possible. Adjust pulley offset and center distance to values as shown.
7. Torque the universal joint bolts (a) to 14 ±1,4 Nm (10±1 ft.lbs.).
b
a
60
CRT 48-33K
wc_gr003775
wc_tx002046gb.fm