Connecting a Terminal
To connect a terminal to the console port using the cable and adapters provided with the
Catalyst 4000 family switch, ensure that the console port mode switch is in the "in" position (factory
default position). Connect to the port using the RJ-45-to-RJ-45 cable and RJ-45-to-DB-25 DTE adapter
or RJ-45-to-DB-9 DTE adapter (labeled "Terminal").
Check the documentation that came with your terminal to determine the baud rate. The baud rate of the
terminal must match the default baud rate (9600 baud) of the console port.
Set up the terminal using the following specifications:
Connecting a Modem
To connect a modem to the console port, ensure that the console port mode switch is in the "in" position
(factory default position). Connect the modem to the port using the RJ-45-to-RJ-45 cable and the
RJ-45-to-DB-25 DCE adapter (labeled "Modem").

Configuring the Management Port

You can download an image to the Catalyst 4000 Layer 3 Services module through the 10/100
management interface by assigning it an IP address.
To configure an IP address on the management port and configure it for Telnet access, perform this
procedure:
Purpose
Step 1
Router # enable
Step 2
Router # configure terminal
Step 3
Router (config)# enable
password password
Step 4
Router (config) # enable
secret password
Step 5
Router (config-if) # interface type
number
Step 6
Router (config-if) #ip address
ip-address subnetmask
Step 7
Router (config-if) #no shutdown
78-10164-03
9600 baud
8 data bits
No parity
1 stop bit
No flow control
Installation and Configuration Note for the Catalyst 4000 Layer 3 Services Module
Accessing the Layer 3 Services Module for the First Time
Command
Enter enable mode.
The # prompt indicates enable mode.
Enter global configuration mode. You can also abbreviate
the command to config terminal. The Router(config)#
prompt indicates that you are in global configuration mode.
Set the enable password.
Enter an enable secret password. A user must enter the
enable secret password to gain access to global
configuration mode.
Enter interface configuration mode on the Ethernet
interface.
Enter the IP address and IP subnet mask for the interface
specified in Step 5.
Enable the interface.