R
epair
[3] -1. Motor section
ASSEMBLING
(5) Mount Cowling complete and Switch button. Fig. 8
Fig. 8
(43)
(6)
(5)
(29)
(7)
Gap
(7)
(43)
No Gap
(5)
(4)
(29)
1. While pulling out Switch D2VW-01-3HS (29)
through the hole of Cowling complete (7), mount
Cowling complete (7).
(7)
2. Tank cover complete (43) and Cowling
complete (7) are about 10mm away because
of Top damper mounted to the reverse side
of Cowling complete (7).
However, there is no problem if the Cowling
complete (7) closely touches Tank cover
complete (43) when it is pushed.
3. Tighten Cowling complete (7) with six 4x65 Tapping
screws (6).
4. Mount 2pcs.of Compression spring 20 (5).
5. Opening the tall rib with Needle-nose pliers,
set Switch (29) to the place where it is,
gripping with external nails of 1R291.
6. Mount Switch button (4).
P 10/ 29
1R291
(29)
Needle-nose pliers