No Intermittent Powerfails
+12 volts measured at
+5 volts measured at
-12 volts measured at -12.00(V)
+24 volts measured at
Air-Flow temperature measured at 32(C)
Inlet
temperature measured at 26(C)
The show environment table command displays the temperature and voltage thresholds for each
monitored status level, which are the same as those listed in Table 1-6 and Table 1-7. The current
measured values are displayed with the unit of measure noted, (V) or (C), and each is listed below a
column heading that indicates its current status level. Measurements that fall within the normal range
are displayed in the Normal column of the table, while measurements that have reached a critical
level are shifted to the Critical column, and so on.
In the following example, all current measured values fall within the normal status range. The first
voltage parameter in the table, +12(V), shows that the normal range for the +12V sense spans
10.20V through 13.80V. The current measured value, 12.05V, falls within that range and is therefore
displayed in the Normal column.
7000# show env table
Environmental Statistics
Environmental status as of Sun 10-25-1992 23:21:42
Data is 19 second(s) old, refresh in 41 second(s)
Voltage Parameters:
SENSE
CRITICAL
-------|--------------------|------------------------|--------------------
+12(V)
+5(V)
-12(V)
+24(V)
Temperature Parameters:
SENSE
WARNING
------|-------------|------------|-------------|--------------|------------
Inlet
Air-flow
12.05(V)
4.82(V)
23.90(V)
NORMAL
10.20
12.05(V)
4.74
4.96(V)
-10.20
-12.05(V)
20.00
23.80(V)
NORMAL
WARNING
10
32(C)
39
10
40(C)
60
CRITICAL
13.80
5.76
-13.80
28.00
CRITICAL
SHUTDOWN
46
64
70
88
Product Overview 1-65