Connecting Interface Cables
Connect the AIP interface cables as shown in Figure 3-4. For detailed descriptions of ATM cabling
requirements, refer to the section "Distance Limitations" in the chapter "Preparing for Installation"
and also the section "AIP Interface Types" in the chapter "Preparing for Installation."
Figure 3-4
Caution
clip (CLIP-E3-EMI) on the receive port (RCVR); the DS3 PLIM connection does not require this
clip. Figure 3-5 shows the EMI filter clip assembly that is required for the E3 PLIM. Do not operate
the E3 PLIM without this assembly.
The E3 and DS3 PLIMs require cable CAB-ATM-DS3/E3. If you have an E3 PLIM, you must
follow steps 1 through 3 to install the CAB-ATM-DS3/E3 cable and EMI filter assembly. If you do
not have an E3 PLIM, proceed to the appropriate section for your configuration.
Step 1
Step 2
3-126 Cisco 700 Hardware Installation and Mainteneance
ATM (AIP) Connections
TAXI 4B/5B with
a multimode MIC
Simplex (2)
Duplex (1)
AIP
To ensure compliance with EMI standards, the E3 PLIM connection requires an EMI filter
Attach the CAB-ATM-DS3/E3 cable to the transmit (XMTR) and receive (RCVR) ports on
the E3 PLIM. (See Figure 3-5a.)
One portion of the cable has a white insulator on both ends to ensure that the
receive-to-transmit and transmit-to-receive relationship is maintained between the E3
PLIM and your ATM switch. The portion of the cable with the white insulator should attach
between receive and transmit or transmit and receive ports of the E3 PLIM and your ATM
switch, respectively.
Hold the EMI filter clip as shown in Figure 3-5b and attach it to the receive cable as shown
in Figure 3-5c.
SONET/SDH
with simplex
SONET/SDH
or duplex SC
with single-mode
connectors
ST2 connectors
AIP
E3 and DS3
with coaxial BNC
AIP
AIP