CIP LEDs

Following are the functions of the CIP LEDs. (See Figure B-7.)
Enabled—Indicates that the CIP has been enabled for operation by the system.
Present—Indicates that the adapter (ECA or PCA) has been detected by the CIP.
Loaded—Indicates that the adapter (ECA or PCA) firmware has been completely loaded.
Signal—For the ECA, this LED indicates that the Sync signal has been detected.
For the PCA, this LED indicates that the Operational Out signal has been detected. Note that even
though a system reset and selective reset both cause the Operational Out signal to drop, the signal
LED will still be on during those sequences.
Online—For the ECA, this LED indicates that an establish-logical-path request has been
received from the channel.
For the PCA, this LED indicates that the PCA is ready to establish connection to the host channel.
Figure B-7
Following are the sequences for the CIP LED indicators. The enabled LED is not part of the
following sequences. On cold boots, the following four LED sequences apply:
CIP LEDs
Interface Processor LEDs
Reading LED Indicators B-269