A.2 List of Flags
A.2.1 High-speed link flags
No.
Keyword
L000000
_HS1_RLINK
L000001
_HS1_LTRBL
L000020
_HS1_STATE
~
[k]
L00009F
(k=000~127)
L000100
_HS1_MOD[k]
~
(k=000~127)
L00017F
L000180
_HS1_TRX[k]
~
(k=000~127)
L00025F
L000260
_HS1_ERR[k]
~
(k=000~127)
L00033F
L000340
_HS1_SETBL
~
OCK[k]
L00041F
[Table 1] List of communication flags based on HS link number (HS link No. 1 ~ 12)
A - 3
Pnet I/F Module 2MLL-PSRA, 2MLL-PMEA, 2MLL-PMEB User's Guide
Type
Detail
HS link parameter
No.1's all stations
Bit
normally operated
After _HS1RLINK
Bit
is ON, abnormal
status displayed
HS link parameter
No.1, Block No.k's
Bit
Array
general status
displayed
HS link parameter
Bit
No.1, Block No.k
station's Run
Array
operation mode
Normal
communication
Bit
displayed with HS
Array
link parameter
No.1, Block No.k
station
HS link parameter
Bit
No.1, Block No.k
station's Run error
Array
mode
HS link parameter
Bit
No.1, Block No.k
Array
setting displayed
Honeywell
Description
Displays all stations normally operated as specified in
HS link parameter, which will be On if
1.there is no error with all stations specified in
parameter in RUN mode
2.All data block is in normal communication as
specified in parameter.
3.The parameter specified in each station itself is in
normal communication. Run_link will be kept On if
once On until stopped by link disenable.
This flag will be On if the station specified in parameter
and the data block's communication status are as
described below with _HSmRLINK flag On,.
1. When the station specified in parameter is not in
RUN mode,
2. When the station specified in parameter is in error,
3. When data block's communication status specified
in parameter is unstable,
The link trouble will be On if one of those conditions
1,2 and 3 above occurs. And if such a condition is
back to normal, it will be Off.
Displays the general status of the communication
information for the specified parameter's respective data
blocks.
HS1STATE[k]=HS1MOD[k]&_HS1TRX[k]&(~_HSmER
R[k])
Displays the operation mode of the station specified in
parameter's data block k.
Displays the communication status of parameter's data
block k to check if normal as specified.
Displays the communication status of parameter's data
block k to check for any error.
Displays the setting status of parameter's data block k.