Figure 18: Unshielded Twisted Pair (Utp) Option - Hd6 Weather Dome - No Connector - Honeywell HD6 Series Installation Manual

Hide thumbs Also See for HD6 Series:
Table of Contents

Advertisement

3.3 WIRING – UNSHIELDED TWISTED PAIR (UTP) OPTION, CONTINUED
CAUTION: VERIFY THE TYPE OF CONNECTOR (14-PIN OR NONE) PRIOR TO
INTERFACE BOARD 518753-1030
W1
W2
W4
SW1
Jumper W1
Terminated
Position 1 & 2 Last Dome on Data Loop
Unterminated
Position 2 & 3 All Intermediate Domes on Data Lo op
Jumper W2
Positions 2 & 3 All Domes
Jumpers W3 & W4
UTP
Positions 1 & 2
Not Used
Positions 2 & 3
To use the board as standard (video over coax & 2-wire RS485):
Jumper W3
Positions 1 & 2
Jumper W4
Positions 2 & 3
DIP Switch
SW1
Control & Video Over UTP
Switch Position
UTP Cable
Feet
Meters
1
0-300
0-90
Off
300-600
90-180
On
600-900
180-270
Off
900-1200
270-365
Off
1200-1500
365-455
Off
* Use lowest switch setting possible.
Ex: If cable run is 900 feet, use 600-900 switch setting.
Make sure only one switch is set to ON.
Note: If an active receiver (e.g., NVT Model NV-652R)
is used at the monitor, set all switches to OFF.
If the compensation is not enough, set SW1-1 to ON.
Ensure all other switches are set to OFF.
TABLE 1
HD6 POWER REQUIREMENTS: 24VAC
24 VAC POWER @1.1A
AWG
MAX. DISTANCE TO DOME
22
65 FEET (19 METERS)
20
100 FEET (30 METERS)
18
160 FEET (48 METERS)
16
260 FEET (79 METERS)
14
420 FEET (128 METERS)
12
650 FEET (198 METERS)
IF YOU ARE USING A 3M OR 10M EXTENSION CABLE, USE THE
WIRING DIAGRAM SUPPLIED WITH THE EXTENSION CABLE.
Figure 18: Unshielded Twisted Pair (UTP) Option – HD6 Weather Dome – No
Rev. 1.02
CONNECTING WIRING OR EQUIPMENT DAMAGE MAY OCCUR.
2
3
4
Off
Off
Off
Off
Off
On
On
Off
Off
Off
On
Off
Off
Off
On
±10%
HEATER/BLOWER POWER REQUIREMENTS: 24VAC @ 4A
24VAC HEATER POWER
MAXIMUM WIRE LENGTHS
AWG
MAX. DISTANCE TO DOME
18
62 FEET (18.9 METERS)
16
99 FEET (30.2 METERS)
14
158 FEET (48.2 METERS)
12
251 FEET (76.5 METERS)
Connector
DOME WIRING, 13.5 (340) LG., SEE BELOW
FEMALE BNC FOR VIDEO
INTERFACE BOARD
HD6 WEATHER DOME WIRING
UTP OPTION (VIDEO ON UNSHIELDED TWISTED PAIR)
24VAC DOME POWER
24VAC DOME POWER
DATA OPTION
WIRING REQUIRES
SPECIAL FIRMWARE
TO 24VAC
HEATER/B LOWER
ASSEMBLY
ALARM 1 OPTION COMMON
ALARM 2 OPTION COMMON
TABLE 2
THERMOSTAT: ON 70
40
THREADED NIPPLE
12.29" REF
(312.2mm)
BLACK
WHITE
BLACK/WHITE
-
DATA RX
BLACK/ORANGE
+
DATA RX
WHITE/BLACK
-
DATA TX
WHITE/VIOLET
+
DATA TX
BROWN
GROUND
RED
24VAC L1
ORANGE
NOT USED
YELLOW
24VAC L2
GREEN
ALARM 1 OPTION
BLUE
ALARM 2 OPTION
VIOLET
NOT USED
GRAY
NOT USED
WHITE/BROWN
WHITE/RED
WHITE/ORANGE
+
VIDEO
(CAT5)
WHITE/YELLOW
-
VIDEO (CAT5)
NOT USED
NOT USED
°F
OFF 9 °F
0
OUTPUT 96W
900.0696
1-Aug-06
1.62"
(41.1mm)
9.54"
(242.3mm)