Hd6 Rugged Housing Installation; Figure 13: Standard Wiring - Hd6 Rugged Housing Installation - Honeywell HD6 Series Installation Manual

Hide thumbs Also See for HD6 Series:
Table of Contents

Advertisement

3.2 WIRING – STANDARD, CONTINUED

3.2.3 HD6 Rugged Housing Installation

Refer to
1. If this is the last dome in a daisy-chain wiring loop, the receive and transmit
communication lines must be terminated. All intermediate domes must be
unterminated. If this is the only dome on a data line, the receive and transmit
communication lines must be terminated.
Install Jumper W1 on pins 1 and 2 (terminated) to terminate the data.
Install Jumper W1 on pins 2 and 3 (unterminated) to unterminate the data.
Install Jumper W2 on pins 2 and 3 for all domes.
2. The HD6 is designed for 2-wire communication. Place Jumpers W3 and W4 on pins
1 and 2.
CONTROL DATA
POWER
F1 1.6A 250V
LED POWER INDICATOR
REMOVABLE TOP PLATE
SPECIFICATIONS
POWER REQUIREMENTS AT DOME: 24VAC, 50/60 Hz, 1.1A
NOTES:
1. TERMINAL STRIPS ACCEPT 18-22AWG WIRE
IF LARGER OR SMALLER WIRE IS REQUIRED, 18-22AWG MUST BE SPLICED
ONTO FIELD WIRE BEFORE INSERTING INTO TERMINAL STRIP.
2. ALL DIMENSIONS IN PARENTHESES ARE IN MILLIMETERS.
3. POWER SOURCE MUST BE 24VAC
4. DATA CABLE SHIELD NOT CONNECTED AT DOME.
Figure 13: Standard Wiring – HD6 Rugged Housing Installation
Rev. 1.02
Figure 13
for installation diagram.
ALARM TERMINAL
STRIP
J4
VIDEO BNC
CONNECTOR
F1
±
10% AT POWER SUPPLY.
TERMINAL STRIP TB1
TB1-1
24Vac
TB1-2
TB1-3
24Vac
TB1-4
RX -
TB1-5
RX+
TB1-6
TX+
TB1-7
TX -
TB1-8
Jumper W1
Terminated
Position 1 and 2 Last Dome on Data Loop
Unterminated Positions 2 and 3 All Intermediate Domes on Data Loop
Jumper W2
Positions 2 and 3 All Domes
Jumpers W3 & W4
2-wire
Positions 1 and 2 All Domes
24 VAC POWER @1.1A
AWG
MAX. DISTANCE TO DOME
22
65 FEET (19 METERS)
20
100 FEET (30 METERS)
18
160 FEET (48 METERS)
16
260 FEET (79 METERS)
14
420 FEET (128 METERS)
12
650 FEET (198 METERS)
29
TERMINAL STRIP TB2
TB2-1
Alarm 1
Ground
TB2-2
Common
TB2-3
Alarm 2
TB2-4
Common
TB2-5
Alarm 3
TB2-6
Common
TB2-7
Alarm 4
No Connection
TB2-8
Common
900.0696
1-Aug-06