Figure 7: Changing Orientation Of The Bracket - Honeywell HD6 Series Installation Manual

Hide thumbs Also See for HD6 Series:
Table of Contents

Advertisement

2.4 HD6 RUGGED DOME HOUSING , CONTINUED
To change orientation of bracket:
1. Remove nuts, lockwashers, and bolts
2. Flip bracket
3. Insert bolts (4) in slots and hole, and
4. Secure with lockwashers and nuts.

Figure 7: Changing Orientation of the Bracket

8. Route the field-run wiring (data, HD6 power, video, and heater or blower power)
through the conduit fitting to the appropriate position on the terminal strips in the
housing. The terminal strips are labeled to show the function of each position.
NOTE: Do not connect the data cable shield at the terminal strip. The terminal
strips TB1 and TB2 accept 18-24 AWG wire. If larger or smaller field-run wire is
required, an 18-24 AWG wire must be spliced onto the field wire for insertion into the
terminal strip.
Refer to
Refer to
Refer to
Refer to
a. Flip up the tab on the terminal strip.
b. Strip the insulation on the wire back approximately 7/16".
c. Insert the wire fully in the hole on the terminal strip to ensure a good contact and
d. Push the tab down to secure the wire.
Rev. 1.02
45 - 90 degrees
0°-90°
Loosen nuts (2 each side)
to slide bracket along slot
to change angle
Section 3
for wiring information.
Section 3.2
for standard wiring.
Section 3.3
for Unshielded Twisted Pair (UTP) wiring.
Figure 8
if the heater/blower or blower option is installed.
to ensure it does not short to adjacent wires.
0 - 45 degrees
13
0°-45°
Loosen nuts (2 each side)
to slide bracket along slot
to change angle
900.0696
1-Aug-06

Advertisement

Table of Contents
loading