3.1 INTRODUCTION

The field wiring for an indoor HD6 is connected at a terminal strip in the housing or
pendant dome. The field wiring for an outdoor HD6 is connected at a CPC connector
(J2) or to fly-leads on the housing. Refer to the information specified in the installation
instructions for wiring connections.

3.1.1 Power

Each camera assembly or scan requires a 24Vac power supply @ 1.1A measured at the
dome.
The following table shows the wire gauge required for maximum distances to maintain
24V ac ± 10% at the dome. These wire sizes and distances represent one power source
for one HD6.
AWG
22
20
18
16
14
12
The power supply on the scan is isolated so more than one scan can be powered from
the same power source.
Rev. 1.02
SECTION 3:
WIRING THE HOUSING
Maximum Distance to Dome
24 VAC
24 VAC
Camera Only
Blower Only
(1.1A)
(0.5A)
65 ft (19m)
150 ft (45m)
100 ft (30m)
235 ft (70m)
160 ft (48m)
375 ft (110m)
260 ft (79m)
600 ft (180m)
420 ft (128m)
950 ft (290m)
650 ft (198m)
1500 ft (455m)
24 VAC
24 VAC
Heater & Blower
Camera plus
Only (4A)
Blower (1.6A)
Not
45 ft (13m)
Recommended
Not
70 ft (21m)
Recommended
62 (19m)
110 (33m)
99 (30m)
175 (53m)
158 (48m)
280 (85m)
251 ft (76m)
450 ft (137m)
19
24 VAC
Camera plus
Heater & Blower
(6.0A)
Not
Recommended
Not
Recommended
Not
Recommended
48 (14m)
75 (22m)
120 (36m)
900.0696
1-Aug-06