Dropped / Hard Ceiling Installation, Continued; Figure 10: Standard Wiring - Dropped / Hard Ceiling Installation - Honeywell HD6 Series Installation Manual

Hide thumbs Also See for HD6 Series:
Table of Contents

Advertisement

3.2 WIRING – STANDARD, CONTINUED

3.2.1 Dropped / Hard Ceiling Installation, Continued

ALIGNMENT TAB
CONTROL DATA
POWER
F1 1.6A 250V
LED POWER INDICATOR
Figure 10: Standard Wiring – Dropped / Hard Ceiling Installation
8. Secure the top plate in the housing.
a. Align the tabs on the plate with the slots in the housing. See
b. Push the field run wiring back through the access hole in the housing.
c. Push the plate up until the spring latch catches and locks the top plate.
Rev. 1.02
CABLE CLAMP
J4
F1
REMOVABLE TOP PLATE
SPECIFICATIONS
WEIGHT : 5.5 lbs. (2.50 kg) WITH CAMERA
POWER REQUIREMENTS AT DOME: 24VAC, 50/60 Hz, 1.1A
NOTES:
1. TERMINAL STRIPS ACCEPT 18-22AWG WIRE
IF LARGER OR SMALLER WIRE IS REQUIRED, 18-22AWG MUST BE SPLICED
ONTO FIELD WIRE BEFORE INSERTING INTO TERMINAL STRIP.
2. ALL DIMENSIONS IN PARENTHESES ARE IN MILLIMETERS.
3. POWER SOURCE MUST BE SUFFICIENT ENOUGH TO MAINTAIN
A 21.6VAC INPUT AT DOME.
24 VAC POWER @1.1A
AWG
MAX. DISTANCE TO DOME
22
65 FEET (19 METERS)
20
100 FEET (30 METERS)
18
160 FEET (48 METERS)
16
260 FEET (79 METERS)
14
420 FEET (128 METERS)
12
650 FEET (198 METERS)
4. DATA CABLE SHIELD NOT CONNECTED AT DOME.
See
Figure
11.
WARNING: Make sure that the top plate is secured in the housing
by gently pulling on the white connector. If the plate comes down
when you gently pull on the connector, the plate is not secured
properly.
ALIGNMENT TAB
TERMINAL STRIP TB1
TB1-1
TB1-2
ALARM TERMINAL
TB1-3
STRIP
TB1-4
TB1-5
TB1-6
TB1-7
VIDEO BNC
TB1-8
CONNECTOR
Jumper W1
Terminated
Position 1 and 2 Last Dome on Data Loop
Unterminated Positions 2 and 3 All Intermediate Domes on Data Loop
Jumper W2
Positions 2 and 3 All Domes
Jumpers W3 & W4
2-wire
Positions 1 and 2 All Domes
25
TERMINAL STRIP TB2
24Vac
TB2-1
Alarm 1
Ground
TB2-2
Common
24Vac
TB2-3
Alarm 2
RX -
TB2-4
Common
RX+
TB2-5
Alarm 3
TX+
TB2-6
Common
TX -
TB2-7
Alarm 4
No Connection
TB2-8
Common
Figure
11.
900.0696
1-Aug-06