2.3 PENDANT DOME HOUSING

WARNING: Installation must be performed by qualified technical
personnel and must be in accordance with all national and local
mechanical and electrical codes.
Perform the following steps to install a HD6 pendant dome on a Honeywell Video
Systems indoor wall or ceiling pendant dome mount:
INSERT PIN FOR
SAFETY CABLE
MOUNTING
HOLES
(3 PLACES)
SPRING LATCH
(RELEASES TOP PLATE)
SCAN ALIGNMENT STUDS
LOWER DOME
MOUNTING POSTS
(3 PLACES)

Figure 3: Pendant Dome Housing Installation

1. Select the location(s) of the housing (s). Each HD6 requires a 24Vac ± 10% power
source measured at the dome. Ensure a 24Vac @ 1.1A power source is available.
2. Install the mount using the instructions provided with your specific mount.
Rev. 1.02
BLACK NIPPLE
TOP PENDANT
HOUSING
7
SAFETY CABLE INSTALLATION
ATTACH THE SAFETY CABLE
TO A BUILDING SUPPORT STRUCTURE
SPLICING SLEEVE
SAFETY CABLE
SPLICING SLEEVE
LOOP AROUND
1/4" DIA x 1-3/4" LG. PIN
INSERTED IN TOP OF DOME
DETAIL A
(SUPPLIED BY INSTALLER)
900.0696