2.3 PENDANT DOME HOUSING, CONTINUED
g. Carefully slide the black nipple on the pendant housing into the mounting pipe.
WARNING: Do not force the dome into the mount; the threads on the
dome are plastic and could be damaged if force is used.
h. Line up the three mounting holes on the housing with the holes in the mount
i.
6. Connect the field wiring to the housing mounting plate (removed in step 5 above).
Refer to
Refer to
Refer to
Rev. 1.02
If installing the dome on a threaded mount, thread the dome into the mount at
this time then connect the safety cable to a building support structure.
piping. Use the three self-tapping hex head screws supplied with the mount to
secure the dome to the mount.
Slide the decorative cover flange on the mount (step 4 above) over the black
nipple on the housing.
Section 3
for wiring information.
Section 3.2
for standard wiring.
Section 3.3
for Unshielded Twisted Pair (UTP) wiring.