Figure 14: Standard Wiring - Hd6 Weather Dome - No Connector - Honeywell HD6 Series Installation Manual

Hide thumbs Also See for HD6 Series:
Table of Contents

Advertisement

3.2 WIRING – STANDARD, CONTINUED
CAUTION: VERIFY THE TYPE OF CONNECTOR (14-PIN OR NONE) PRIOR TO
HD6 WEATHER DOME WIRING
24VAC DOME POWER
24VAC DOME POWER
TO 24VAC
HEATER/BLOWER
ASSEMBLY
ALARM 1 OPTION
ALARM 2 OPTION
ALARM 3 OPTION
ALARM 4 OPTION
ALARM 1 OPTION COMMON
ALARM 2 OPTION COMMON
ALARM 3 OPTION COMMON
ALARM 4 OPTION COMMON
VIDEO SHIELD
HD6 POWER REQUIREMENTS: 24VAC
24 VAC POWER @1.1A
AWG
MAX. DISTANCE TO DOME
22
65 FEET (19 METERS)
20
100 FEET (30 METERS)
18
160 FEET (48 METERS)
16
260 FEET (79 METERS)
14
420 FEET (128 METERS)
12
650 FEET (198 METERS)
HEATER/BLOWER POWER REQUIREMENTS: 24VAC @ 4A
24VAC HEATER/BLOWER POWER
MAXIMUM WIRE LENGTHS
AWG MAX. DISTANCE TO DOME
18
62 FEET (18.9 METERS)
16
99 FEET (30.2 METERS)
14
158 FEET (48.2 METERS)
12
251 FEET (76.5 METERS)
IF YOU ARE USING A 3M OR 10M EXTENSION CABLE, USE THE WIRING DIAGRAM SUPPLIED
WITH THE EXTENSION CABLE.
Figure 14: Standard Wiring – HD6 Weather Dome – No Connector
Rev. 1.02
CONNECTING WIRING OR EQUIPMENT DAMAGE MAY OCCUR.
FEMALE BNC FOR VIDEO
BLACK
WHITE
BLACK/WHITE
DATA RX-
BLACK/ORANGE
DATA RX+
WHITE/BLACK
DATA OPTION WIRING
DATA TX-
(REQUIRES SPECIAL
WHITE/VIOLET
DATA TX+
FIRMWARE)
BROWN
GROUND
RED
24VAC L1
ORANGE
NOT USED
YELLOW
24VAC L2
GREEN
BLUE
VIOLET
GRAY
WHITE/BROWN
WHITE/RED
WHITE/ORANGE
WHITE/YELLOW
VIDEO
BNC
VIDEO
CONNECTOR
VIDEO SHIELD
TABLE 1
±10%
TABLE 2
THERMOSTAT:
DOME WIRING, 13.5 (340) LG., SEE BELOW
INTERFACE BOARD
518245-2030
F1 1.6A 250V
LED POWER
INDICATOR
Jumper W1
Terminated
Position 1 and 2 Last Dome on Data Loop
Unterminated Positions 2 and 3 All Intermediate Domes on Data Loop
Jumper W2
Positions 2 and 3 All Domes
Jumpers W3 & W4
2-wire
Positions 1 and 2 All Domes
ON 70
°F
OFF 9 °F
0
OUTPUT 96W
31
THREADED NIPPLE
18-22 AWG WIRE
WIRING ENTERS
FROM THIS SIDE
900.0696