Chapter 2
Alarm Troubleshooting
2.7.43 DATAFLT
The Software Data Integrity Fault alarm occurs when the ONS 15310-MA SDH exceeds its flash
memory capacity.
Clear the DATAFLT Alarm
Complete the
Step 1
Avoid soft-resetting multiple ONS 15310-MA SDH cards at one time; doing so might cause an
Caution
unexpected traffic hit.
If the alarm does not clear, log into the Technical Support Website at
Step 2
http://www.cisco.com/cisco/web/support/index.html for more information or call Cisco TAC
(1-800-553-2447).
2.7.44 DBOSYNC
The Standby Database Out Of Synchronization alarm applies to the ONS 15310-MA SDH platform and
occurs when the standby ONS 15310-MA SDH database does not synchronize with the active database
on the active ONS 15310-MA SDH.
If you reset the active ONS 15310-MA SDH while this alarm is raised, you will lose current
Caution
provisioning.
Clear the DBOSYNC Alarm
Step 1
Save a backup copy of the active ONS 15310-MA SDH database. Refer to the "Maintain the Node"
chapter in the Cisco ONS15310-MA SDH Procedure Guide for procedures.
Step 2
Make a minor provisioning change to the active database to see if applying a provisioning change clears
the alarm:
a.
b.
78-18663-01
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
SDH Logical Object: NE
"Soft- or Hard-Reset a Controller Card" procedure on page
Default Severity: Major (MJ), Service-Affecting (SA)
Logical Object: NE
In node view, click the Provisioning > General > General tabs.
In the Description field, make a small change such as adding a period to the existing entry.
The change causes a database write but does not affect the node state. The write could take up to a
minute.
Cisco ONS 15310-MA SDH Troubleshooting Guide, Release 9.0
Alarm Procedures
2-152.