Alarm Procedures
2.7.233 VCG-DEG
The VCAT Group Degraded alarm is a VCAT group alarm. The condition occurs when one member
circuit carried by the ML-100T-8 or CE-Series card is down. If a member fails in the VCG and some
members are error free then this alarm occurs and is applicable for LCAS and SW-LCAS. This condition
is accompanied by the
For more information about Ethernet cards, refer to the Cisco ONS 15310-CL and Cisco ONS 15310-MA
Note
Ethernet Card Software Feature and Configuration Guide.
Clear the VCG-DEG Condition
Step 1
Look for and clear any Critical (CR) alarms that apply to the errored card or port.
If the condition does not clear, log into the Technical Support Website at
Step 2
http://www.cisco.com/cisco/web/support/index.html for more information or call Cisco TAC
(1-800-553-2447).
2.7.234 VCG-DOWN
The VCAT Group Down alarm is a VCAT group alarm. The condition occurs when all members fail in
the LCAS/SW-LCAS circuit or even when one member fails in the NO-LCAS circuit type carried by the
ML-100T-8 or CE-Series card. This condition occurs in conjunction with another Critical (CR) alarm.
For more information about Ethernet cards, refer to the Cisco ONS 15310-CL and Cisco ONS 15310-MA
Note
Ethernet Card Software Feature and Configuration Guide.
Clear the VCG-DOWN Condition
Complete the
Step 1
If the condition does not clear, log into the Technical Support Website at
Step 2
http://www.cisco.com/cisco/web/support/index.html for more information or call Cisco TAC
(1-800-553-2447).
Cisco ONS 15310-MA SDH Troubleshooting Guide, Release 9.0
2-144
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SDH Logical Object: VCG
"OOU-TPT" alarm on page
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SDH Logical Object: VCG
"Clear the VCG-DEG Condition" procedure on page
Chapter 2
2-112.
2-144.
Alarm Troubleshooting
78-18663-01