Chapter 2
Alarm Troubleshooting
The alarm does not require user intervention. If the alarm does not clear, log into the Technical Support
Note
Website at http://www.cisco.com/cisco/web/support/index.html for more information or call Cisco TAC
(1-800-553-2447).
2.7.165 MFGMEM
The Manufacturing Data Memory Failure alarm occurs when the electronically erasable programmable
read-only memory (EEPROM) fails on a card or component, or when the ONS 15310-MA SDH cannot
read this memory. EEPROM stores manufacturing data that a 15310-MA-CTX card uses to determine
system compatibility and shelf inventory status. Unavailability of this information can cause
less-significant problems.
To clear the MFGMEM alarm, log into the Technical Support Website at
http://www.cisco.com/cisco/web/support/index.html for more information or call Cisco TAC
(1-800-553-2447) to report a Service-Affecting (SA) problem.
2.7.166 NO-CONFIG
The No Startup Configuration condition applies to ML-100T-8 Ethernet cards and occurs when no
startup configuration file has been downloaded to the ONS 15310-MA SDH, whether or not you
preprovision the card slot. This alarm can occur during provisioning. When the startup configuration file
is copied to the ONS 15310-MA SDH, the alarm clears.
For more information about Ethernet cards, refer to the Cisco ONS 15310-CL and Cisco ONS 15310-MA
Note
Ethernet Card Software Feature and Configuration Guide.
Clear the NO-CONFIG Condition
Create a startup configuration for the card in Cisco IOS.
Step 1
General ML-100T-8 provisioning parameters are located in the Cisco ONS 15310-CL and
Cisco ONS 15310-MA Ethernet Card Software Feature and Configuration Guide. The Guide also
contains information about where to find additional IOS information.
Upload the configuration file to the controller card by completing the following steps:
Step 2
a.
b.
c.
Step 3
Complete the
78-18663-01
Default Severity: Critical (CR), Service-Affecting (SA)
SDH Logical Objects: BPLANE, FAN, PPM
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SDH Logical Object: EQPT
In node view, right-click the ML-100T-8 Ethernet card graphic.
Choose IOS Startup Config from the shortcut menu.
Click Local > CTX and navigate to the file location.
"Soft- or Hard-Reset an Ethernet or Electrical Card in CTC" procedure on page
Cisco ONS 15310-MA SDH Troubleshooting Guide, Release 9.0
Alarm Procedures
2-151.
2-111