Alarm Procedures
If the condition does not clear, log into the Technical Support Website at
Step 5
http://www.cisco.com/cisco/web/support/index.html for more information or call Cisco TAC
(1-800-553-2447).
2.7.211 SWMTXMOD-PROT
The Switching Matrix Module Failure on Protect Slot alarm is raised by the Slot 4 ONS 15310-MA SDH
if this card is active (ACT). SWMTXMOD-PROT occurs when a logic component internal to the is out
of frame (OOF) with a traffic card in the system. In this case, the alarm is raised against the traffic card
slot.
Clear the SWMTXMOD-PROT Alarm
Complete the
Step 1
card. For the LED behavior, see the
page
Step 2
Verify that the reset is complete and error-free and that no new related alarms appear in CTC. A green
ACT/SBY LED indicates an active card. An amber ACT/SBY LED indicates a standby card.
Step 3
If the alarm does not clear, complete the
procedure for the Slot 4 controller card.
If the alarm does not clear, log into the Technical Support Website at
Step 4
http://www.cisco.com/cisco/web/support/index.html for more information or call Cisco TAC (1 800
553-2447) in order to report a Service-Affecting (SA) problem.
2.7.212 SWMTXMOD-WORK
The Switching Matrix Module Failure on Working Slot alarm is raised by the ONS 15310-MA SDH
when a logic component internal to the card's cross connect is OOF with a traffic card in the system. In
this case, the alarm is raised against the traffic card slot.
Clear the SWMTXMOD-WORK Alarm
Complete the
Step 1
the controller card. For the LED behavior, see the
section on page
Verify that the reset is complete and error-free and that no new related alarms appear in CTC. A green
Step 2
ACT/SBY LED indicates an active card. An amber ACT/SBY LED indicates a standby card.
Cisco ONS 15310-MA SDH Troubleshooting Guide, Release 9.0
2-132
Default Severity: Critical (CR), Service-Affecting (SA)
SDH Logical Object: EQPT
"Soft- or Hard-Reset a Controller Card" procedure on page 2-152
2-146.
Default Severity: Critical (CR), Service-Affecting (SA)
SDH Logical Object: EQPT
"Soft- or Hard-Reset an Ethernet or Electrical Card in CTC" procedure on page 2-151
2-146.
"2.8.2 Typical Card LED Activity During Reset" section on
"Remove and Reinsert (Reseat) a Card" section on page 2-153
"2.8.2 Typical Card LED Activity During Reset"
Chapter 2
Alarm Troubleshooting
procedure for the Slot 4
78-18663-01
for