Honeywell KHF 1050 System Installation Manual page 45

Hf communication system
Hide thumbs Also See for KHF 1050:
Table of Contents

Advertisement

AIRCRAFT EQUIPMENT
High Voltage HN Cables:
(cont)
155-02989-0001
155-0302X-XXXX
088-03514-0000
Miscellaneous
NOTE:
Other HN cable assembly configurations may be available. Contact Honeywell.
* Cable Specification AN-J-C-48
** Single Cable in free air.
*** Cable in conduit or bundles with only three cables, or 20 percent of the bundle,
whichever is greater.
Table 22 - Equipment Required But Not Supplied
WARNING: THE HIGH VOLTAGE HN CABLES ARE SPECIFICALLY
Revison 2
N
KHF 1050 SYSTEM INSTALLATION MANUAL
Equipment Required But Not Supplied
Designed for dual 1050 installations.
Total length is approximately 15.5" (39.4 cm).
Common leg is 6" (15.24 cm).
Each separate leg is 9" (22.9 cm).
All three connectors are straight.
An insulating cap is included to allow this cable to be
used with one KHF 1050 system temporarily removed
from the installation.
See
"Figure 1 - Typical System"
Weight = 1.2 lbs.
For use with antennas that do not exceed 2800 Vac peak.
HN Y-Cable Assembly - See
Dual Coupler Cables"
HN CAP - See
Feedline Considerations"
installation hardware, mounting brackets, wire, cables,
nuts, bolts
DESIGNED TO WITHSTAND THE HIGH RF VOLTAGE
GENERATED BY THE KHF 1050 SYSTEM. THEY CAN NOT BE
REPLACED BY CABLES THAT HAVE NOT BEEN TESTED TO
THESE HIGH VOLTAGES AT ALTITUDE. THESE CABLES
SHOULD BE PURCHASED DIRECTLY FROM HONEYWELL, OR
FROM THE QUALIFIED VENDOR (CATON CONNECTOR CORP,
26 WAPPING ROAD, KINGSTON, MA, 02364, 781-585-4315).
DESCRIPTION
.
"Figure 8 - High Voltage
.
Paragraph "5.C.(6) Dual Installation
23-10-09
Page 19