Honeywell KHF 1050 System Installation Manual page 134

Hf communication system
Hide thumbs Also See for KHF 1050:
Table of Contents

Advertisement

8.C.
KRX 1053 Receiver/Exciter Removal and Re-installation
8.C.(1)
KRX 1053 Receiver/Exciter Removal
Detach cables from connector J10531.
Detach the coaxial cable from J10532.
Loosen retaining screw clamp located at the front of the KRX 1053
Receiver/Exciter. Remove unit from mounting rack.
8.C.(2)
KRX 1053 Receiver/Exciter Re-installation
Slide the KRX 1053 Receiver/Exciter gently into the mounting tray.
Engage and tighten retaining screw clamps to secure unit.
Reconnect appropriate cables to connector J10531.
Reconnect the coaxial cable to J10523.
8.D.
Compatible Control Unit Removal and Re-installation
8.D.(1)
PS440 Removal and Re-installation
8.D.(1)(a)
Removal
Loosen two Allen head screws that are recessed into the front bezel.
Pull the PS440 out of the instrument panel.
Remove locking devices at connector J1.
Disconnect mating connector from connector J1.
8.D.(1)(b)
Re-installation
Reconnect mating connector to connector J1.
Secure locking devices at connector J1.
Insert the PS440 into the instrument panel.
Tighten the two Allen head screws that are recessed into the front bezel.
8.D.(2)
MC-850 Removal and Re-installation
Refer to the MC-850 installation documentation pertinent to each specific
application for MC-850 MCDU removal and re-installation instructions.
8.D.(3)
RM-855 Removal and Re-installation
Refer to the Primus
Installation Manual, P/N A15-3800-001, for RM-855 Radio Management Unit
removal and re-installation instructions.
Revison 2
N
KHF 1050 SYSTEM INSTALLATION MANUAL
®
II SRZ-85X Integrated Radio System Operation and
23-10-09
Page 2052
Apr/2006

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents