Apr/2006 - Honeywell KHF 1050 System Installation Manual

Hf communication system
Hide thumbs Also See for KHF 1050:
Table of Contents

Advertisement

AIRCRAFT EQUIPMENT
16 AWG
10 AWG
8 AWG
24 AWG
18 AWG
24 AWG
24 AWG
CABLE:
AN-22a
AN-20
AN-18
AN-16
Revison 2
N
KHF 1050 SYSTEM INSTALLATION MANUAL
Equipment Required But Not Supplied
Single conductor P/N 025-00091-0004
Single conductor P/N 025-00091-0007
Single conductor P/N 025-00091-0008
Single conductor with shield and jacket P/N
025-05018-0000
Single conductor with shield and jacket P/N
025-05019-0000
Two conductor with shield and jacket P/N
025-05020-0000
Three conductor with shield and jacket P/N
025-05023-0000
755 Nominal Circular Mil Area*
0.090 inches Max. Overall Diameter
16.45 ohms Max. per 1000 feet @ 20°C
8 amps Max. Cont. Current Rating**
5 amps Max. Cont. Current Rating***
1,200 Nominal Circular Mil Area*
0.100 inches Max. Overall Diameter
10.25 ohms Max. per 1000 feet @ 20°C
11 amps Max. Cont. Current Rating**
7.5 amps Max. Cont. Current Rating***
1,909 Nominal Circular Mil Area*
0.115 inches Max. Overall Diameter
6.44 ohms Max. per 1000 feet @ 20°C
16 amps Max. Cont. Current Rating**
10 amps Max. Cont. Current Rating***
2,409 Nominal Circular Mil Area
0.130 inches Max. Overall Diameter
4.76 ohms Max. per 1000 feet @ 20°C
22 amps Max. Cont. Current Rating**
13 amps Max. Cont. Current Rating***
DESCRIPTION
23-10-09
Page 17

Apr/2006

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents