3.7 Touchpoint Pro Battery Box

Note: the following safety symbols are used on or within the Touchpoint Pro Battery Box:
Keep away from
No naked Flames
Children
3.7.1 Siting considerations
When choosing a location for the Touchpoint Pro Battery Box, consider the following:
• The Touchpoint Pro Battery Box is specified for operation in ambient temperatures from -20°C to +45°C.
Operation of the unit outside of this temperature range invalidates the warranty and certification.
• The Touchpoint Pro Battery Box must be installed in a Pollution Degree 2 environment as defined by IEC
61010-1 (CSA-C22.2 No 61010, ANSI/ISA 61010-1(82.02.01)), i.e. an environment such as an office or
control room.
The Touchpoint Pro Battery Box is designed for permanent connection to the Touchpoint Pro System
UPS for continuous operation. The maximum cable length between the Touchpoint Pro Battery Box and
the Touchpoint Pro System UPS is 5 m. Wire size must be 4 mm
The Touchpoint Pro Battery Box should be installed only on a vertical surface avoiding sloping surfaces.
Only use the mounting brackets supplied with the apparatus, and follow installation instructions.
• The mounting surface should be flat, and strong enough to bear the weight of the Touchpoint Pro
system. Drywall / plasterboard, dry lined or timber framed type construction is not considered to be a
suitable structural material, unless strengthened with additional supports or braces and/or special
fixings. Take account of the contents and external cabling in addition to the weight of the unit itself.
The Touchpoint Pro Battery Box should have a clearance of 200 mm to either side, and there should be
no heat sources below or adjacent to the unit.
Ensure access to disconnecting device (switch inside the enclosure)
3.7.2 Installation and Assembly
Due to regulations on shipping batteries, which are classified as hazardous goods, it is not possible to
ship the Touchpoint Pro Battery Box as a complete assembly. It is necessary to fit the batteries into the
enclosure, and fit the connecting cables supplied. For safety reasons, it is recommended that the 17 Kg
batteries are installed after mounting the housing on the wall.
Caution: The batteries within the Touchpoint Pro Battery Box have a limited storage life. Please
ensure that the Battery Box is connected and charged within 3 months of delivery.
3.7.2.1 Mounting the Touchpoint Pro Battery Box to a wall
Caution: The assembled Touchpoint Pro Battery Box is heavy (>25 kg or >15 kg, single person lift is
not recommended). Before lifting the enclosure, consider and implement control measures to reduce
the risk of injury. Refer to local safety regulations.
Warning
Warning
Electric Shock
39
Operating Instructions
Read Instructions
2
.
Touchpoint Pro
Wear Eye Protection

Advertisement

Table of Contents
loading

Table of Contents