Table B-5 Ons 15600 Port And Cross-Connect Service State Transitions - Cisco ONS 15600 Reference Manual

Hide thumbs Also See for ONS 15600:
Table of Contents

Advertisement

B.3.2 Port and Cross-Connect Service State Transitions
Table B-5
Current Service State
IS-NR
OOS-AU,AINS
OOS-AU,AINS & FLT
OOS-AU,FLT
OOS-AUMA,FLT & LPBK &
MT
Cisco ONS 15600 Reference Manual, R8.0
B-6
ONS 15600 Port and Cross-Connect Service State Transitions
Action
Put the port or cross-connect in
the OOS,MT administrative
state.
Put the port or cross-connect in
the IS,AINS administrative state.
(Cross-connect only) Put the
cross-connect in the
OOS,DSBLD administrative
state.
Put the port or cross-connect in
the IS administrative state.
Put the port or cross-connect in
the OOS,MT administrative
state.
Put the port or cross-connect in
the OOS,DSBLD.
Alarm/condition is raised.
Alarm/condition is cleared.
Put the port or cross-connect in
the IS administrative state.
Put the port or cross-connect in
the OOS,DSBLD administrative
state.
Put the port or cross-connect in
the OOS,MT administrative
state.
Alarm/condition is cleared.
Put the port or cross-connect in
the IS,AINS administrative state.
Put the port or cross-connect in
the OOS,DSBLD administrative
state.
Put the port or cross-connect in
the OOS,MT administrative state
Release the loopback.
Alarm/condition is cleared.
Appendix B Administrative and Service States
Next Service State
OOS-MA,MT
OOS-AU,AINS
OOS-MA,DSBLD
OOS-MA,DSBLD & OOG for a
VCAT cross-connect
IS-NR
OOS-MA,MT
OOS-MA,DSBLD
OOS-AU,AINS & FLT
OOS-AU,AINS
OOS-AU,FLT
OOS-MA,DSBLD
OOS-AUMA,FLT & MT
IS-NR
OOS-AU,AINS & FLT
OOS-MA,DSBLD
OOS-AUMA,FLT & MT
OOS-AUMA,FLT & MT
OOS-MA,LPBK & MT

Advertisement

Table of Contents
loading

Table of Contents