Access Passwords - GE 339 Instruction Manual

Motor protection system/motor protection and control
Hide thumbs Also See for 339:
Table of Contents

Advertisement

S1 RELAY SETUP

Access passwords

6–10
Changing the Local or Remote Setpoint Password, depending on the interface being
accessed
CONTROL LEVEL
Reset command
Open and Close Breaker commands
Virtual Input commands
Clearing of event records, transient records, and other data
Uploading new firmware
Changing the Local or Remote Control Password, depending on the interface being
accessed
MASTER LEVEL
Setting and changing of all passwords including the Master Reset Password
Disabling password security
All Setpoint and Control Level access rights
For details on Password Security setup and handling using the EnerVista Setup software,
refer to Chapter 3.
This section allows the user to change the Local Setpoint and Local Control Passwords.
The local user may change a local password from the keypad if all of the following are true:
Security is enabled
A valid local setpoint (or local control) password has initially been set
The remote user has the Overwrite Local Passwords setpoint set to NO
The local user knows the current local password.
For more details on the Password Security feature, refer to Chapter 3.
Figure 3: Menu for handling password security using keypad
S1 LOCAL PASSWORDS
LOC SETPOINTS PSWD
LOC CONTROLS PSWD
896747.cdr
The following steps describe how to change the Local Setpoints Password from the
keypad. Similar steps are followed to change the Local Control Password.
ENTER OLD PASSWORD
The user is prompted to enter the current Local Setpoints Password. User the value up/
down keys to select characters, and use the message left/right keys to move the cursor.
Press the Enter key when done. An INVALID PASSWORD message will appear if a wrong
password is entered, security is disabled, the password has not been originally set, or the
local user does not have the rights to change the password. In addition, the user will be
automatically logged out of security from the keypad. If the correct password was
entered, the user is now logged in to the Setpoints Level from the keypad, and will be
prompted to enter a new password.
S1 LOC SETPOINTS PSWD
ENTER OLD PASSWORD
ENTER NEW
PASSWORD
CONFIRM NEW
PASSWORD
S1 LOC CONTROLS PSWD
ENTER OLD PASSWORD
ENTER NEW PASSWORD
CONFIRM NEW PASSWORD