Section 4: Operating Instructions

4.1 Main Control Panel Keypad Labels

The ECC-50/100 is shipped with slide-in labels installed in the keypad as illustrated in the follow-
ing figure. Blank labels are provided to allow the user to customize the zone and message descrip-
tion. Remove the center piece to access the label slots. Using a small, flat screwdriver, press and
release the small plastic latch located on the left side of the center piece. The top row of labels can
be easily removed by sliding them down through the slots in the middle of the keypad and installed
by sliding them up. The bottom row of labels can be removed by sliding them up through the slots
in the middle of they keypad and installed by sliding them down into position.

4.2 ECC-50/100 Switch Functions

The ECC-50/100 display consists of 38 tactile push-button keys. Pressing one or more of the keys
while the panel is not in alarm will select the corresponding circuit for paging or to generate a man-
ually activated evacuation or drill signal. If the panel is in alarm, pressing a key corresponding to an
activated speaker circuit will turn off the circuit and turn on the Trouble LED.
All Call
Pressing this button activates all speaker circuits (that were not manually deactivated) for broad-
cast. ALL CALL paging from the main console's microphone will override paging/manual activa-
tion operations initiated from the other consoles (ECC-LOC, ECC-RPU, ECC-RM) or from a
FACP (if programmed for priority to do so). If all consoles in the system are programmed for equal
priority then the ALL CALL will only occur when the system is not already in use ("System in
Use" LED is not on, remote console active LED is not on). Refer to the SYSTEM CONTROL but-
84
MNS
CONTROL
SPEAKER
ZONE 13
SPEAKER
Install
ZONE 14
SPEAKER
ZONE 15
SPEAKER
ZONE 16
SPEAKER
ZONE 17
SPEAKER
ZONE 18
SPEAKER
ZONE 19
SPEAKER
ZONE 20
SPEAKER
ZONE 21
SPEAKER
ZONE 22
SPEAKER
ZONE 23
SPEAKER
Remove
ZONE 24
TROUBLE SILENCE
REMOTE AMPS
AC POWER
DIST. AMP 1
GROUND FAULT
DIST. AMP 2
CHARGER FAULT
DIST. AMP 3
BATTERY FAULT
DIST. AMP 4
DATA BUS FAULT
DIST. AMP 5
NAC FAULT
DIST. AMP 6
NAC ACTIVE
DIST. AMP 7
SYSTEM TROUBLE
DIST. AMP 8
AUDIO RISER FAULT
Figure 4.1 Keypad Labels
Emergency Command Center Manual — P/N LS10001-000FL-E:G 5/3/2016
OK TO PAGE
MICROPHONE
TROUBLE
MESSAGE 1
MESSAGE 2
MESSAGE 3
MESSAGE 4
MESSAGE 5
MESSAGE 6
MESSAGE 7
Remove
Install