E-10 Single-Board Mirrored Memory Leds - HP ProLiant DL580 Setup And Installation Manual

Generation 2 server
Hide thumbs Also See for ProLiant DL580:
Table of Contents

Advertisement

Table E-10: Single-Board Mirrored Memory LEDs
Item
Description
1 – 4
DIMMs 1 – 8
and
10 – 13
6
Memory
Status
7
Ready to Hot
Plug
9
Mirroring
Status
All LEDs
HP ProLiant DL580 Generation 2 Server Setup and Installation Guide
Indicator
Status
Off
DIMM is not installed.
Green
DIMM is installed.
Amber
Memory error has occurred on this DIMM.
Flashing amber
Configuration error has occurred.
Off
Memory board is offline.
Green
Memory board is online.
Flashing green
Memory board is busy.
Amber
Memory error has occurred on this memory board.
Off
Do not remove memory board—single-board mirrored
memory does not support hot-plug capability.
Off
Memory board is not configured for mirrored memory.
Green
Single-board mirrored memory is functioning properly.
Amber
Memory error has occurred and system has failed over
to the mirrored bank.
Off
Memory board is not seated properly or locking switch
is not engaged; memory board can be removed safely.
Flashing amber
CAUTION: Memory board is in use; relock it
immediately.
System LEDs and Switches
E-11

Advertisement

Table of Contents
loading

Table of Contents