3.10 Specific
Switch
Settings
3.11 The initial (normal)
setting of the switches
is
shown
by a
l
symbol.
The upper case "S" indi-
cates the switch, and the lower case "s" indicates
the function
setting on the switch.
1) Sl-Mode
selection
switch:
sl
: l
ON-Robbed
bit signaling
(normal)
OFF-Future
operation
s2:
l
ON-Zero
Code Suppression
(ZCS)
OFF-Binary
Eight Zero Suppression
(B8ZS)
NOTE:
Must check and match other side.
s3:
ON-Future
operation
l
OFF-Normal
operation
s4:
Not used
2) S2-Transmit
Equalizer
setting
switch (dis-
tancefrom
PERCEPTIONe&ex
to another PBX
if CSWDSU
is not used). (See Table 1.)
IMPORTANT
NOTE:
The
maximum
distance
between
PERCEPTIONHex
and the CSWDSU
is 30
feet. Toshiba
provides
the proper
cable for
this connection
with each NDTU PCB. Its
installation
is required
forproper
operation.
3) S3-NDTU
slot position:
The NDTU PCB can be positioned
in slots TOO
and
T08, in the main or expansion
cabinet,
respectively.
This switch turns on the digital
trunks in increments
of 4. To use all 24 digital
trunks, S3-(sl
w s6) must be ON. To activate
12 digital trunks,
S3-(sl
M s3) must be ON.
(See Table 2.)
ON-Digital
Trunk active
OFF-Digital
Trunk disabled