TABLE 11-3
Procedure - Modem Pooling Data Block
Authorization
Procedure
must be completed.
If an
OK
response
is received,
proceed
as follows:
ITEM
PROMPT
USER ENTRY
NOTE
OK
DMDM
- DISK LOADING -
REQ
NEW, OUT
Port Number
POR
LNNX
l&2
NOTES:
1. NN = PCB location.
PERCEPTION,
- LOO - Ll7/L75
- L26.
PERCEPTION,,
- LOO - L31.
2. X = Circuit number
(1 - 4).
ignore line entered.
Backspace.
Stop printing
and return to REQ.
Exit program.
Error Codes
Error Code
Program
Name:
Modem Pooling Data Block (DMDM)
Meaning
ERMDP 00
A PCB is not equipped in that location.
ERMDP 01
The PCB is not an NMDU tvoe.
ERMDP 02
1 The port is busy (REQ = CHG or OUT).
ERMDP 03
ERMDP 04
The port has already been assigned to a station, DSS console, or DIU (REQ = NEW).
The port is not assigned (REQ) = OUT).
ERMDP 05
ERMDP 06
The input port is wrong (LNNX, X is not 1 - 4).
The port has already been assigned to an attendant console.
ERMDP 07
ERMDP 08
The input port is not a modem pooling port (NMDM).
The port has already been assigned to a trunk.
11-8