PROGRAMMING PROCEDURES
SECTION 200-255-307
JANUARY 1993
Classes 0 - 7 are defined
in the Toll Restriction
Data Block
Class 8 = Dia/m or 0 restriction.
NONE = No Toll Restriction.
Ignore line entered.
Backspace.
Stop printing
and return to REQ.
Exit program.
TABLE 7-3 (continued)
Error Codes
(DTOL Program).
Error Code
1
Program
Name:
Standard
Telephone
Data block (DSlT)
Meanina
ERSTA 00
No PCB is equipped at that location.
ERSTA 01
The PCB is an NEKU type (not an NSTU).
ERSTA 02
Port is busy (REQ = CHG, OUT).
ERSTA 03
Port has already been assigned to a station, DSS console, or DDIU.
ERSTA 05
1 was entered, but tenant service was not enabled in the System Data Block.
ERSTA 06
1 was entered, but ATT #l was not programmed
(no Attendant
Data Block).
ERSTA 09
1
Unknown input.
ERSTA 10
ERSTA 11
DN conflicts with existing DN.
510 DNs have already been assigned in the system.
ERSTA 12
ERSTA 13
DN has already been assigned to the maximum number of appearances
(96).
Hot Line DN does not exist.
ERSTA 14
1
Next Hunt DN does not exist.
ERSTA 17
ERSTA 18
ERSTA 19
MNL 0 was entered, but ATO is not equipped.
MNL 1 was entered, but ATT1 is not equipped.
MNL 0 was entered, but this station is in tenant group #l.
ERSTA 20
1
MNL 0 was entered, but this station is in tenant group #2.
I
ERSTA 21
ERSTA 22
ERSTA 23
ERSTA 24
Input data was erased because the program was aborted during NEW data entry.
The port is not assigned.
Another type of data (electronic telephone,
etc.) is assigned to the input port.
SDC has already been assigned to the input list.
ERSTA 25
I
The next input hunt DN is a trunk DN.
ERSTA 26
ERSTA 27
ERSTA 28
ERSTA 29
ERSTA 30
ERSTA 31
The Distributed Hunt Group has already been assigned its maximum member number (8),
invalid Toll Class Number (0 - 8).
The first digit does not match with RM PFX, or the second digit conflicts with
another DN or access code.
The port has already been assigned to a trunk.
The entry should be ATT (0 and/or 1 not required).
Port has already been assigned as an announcement
port.